The amount of xenon in otherwise very pure krypton can be reduced from 1.5 to 0.0025 per cent approximately by passage through an activated carbon column at dry-ice temperature. The circulation of the krypton is effected by condensing at -196 deg. C and then evaporating. (author) [French] Le taux de xenon dans du krypton par ailleurs tres pur est ramene de 1,5 pour cent a 0,0025 pour cent environ au cours d'un passage a travers une colonne de charbon actif a la temperature de la carboglace. La circulation du krypton se fait par condensation a -196 deg. C, puis evaporation. (auteur)
Authors:
Larher, Y; [1]  Institut Fourier, 38 - Grenoble (France)]
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1961
Product Type:
Technical Report
Report Number:
CEA-R-2111
Resource Relation:
Other Information: 2 refs
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; ACTIVATED CARBON; ADSORPTION; KRYPTON; PURIFICATION; SEPARATION PROCESSES; TEMPERATURE RANGE 0065-0273 K; XENON
OSTI ID:
20740231
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R2111050047
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
8 pages
Announcement Date:
Jun 16, 2006

Citation Formats

Larher, Y, and Institut Fourier, 38 - Grenoble (France)]. Krypton purification (1961); Purification du krypton (1961). France: N. p., 1961. Web.
Larher, Y, & Institut Fourier, 38 - Grenoble (France)]. Krypton purification (1961); Purification du krypton (1961). France.
Larher, Y, and Institut Fourier, 38 - Grenoble (France)]. 1961. "Krypton purification (1961); Purification du krypton (1961)." France.
@misc{etde_20740231,
title = {Krypton purification (1961); Purification du krypton (1961)}
author = {Larher, Y, and Institut Fourier, 38 - Grenoble (France)]}
abstractNote = {The amount of xenon in otherwise very pure krypton can be reduced from 1.5 to 0.0025 per cent approximately by passage through an activated carbon column at dry-ice temperature. The circulation of the krypton is effected by condensing at -196 deg. C and then evaporating. (author) [French] Le taux de xenon dans du krypton par ailleurs tres pur est ramene de 1,5 pour cent a 0,0025 pour cent environ au cours d'un passage a travers une colonne de charbon actif a la temperature de la carboglace. La circulation du krypton se fait par condensation a -196 deg. C, puis evaporation. (auteur)}
place = {France}
year = {1961}
month = {Jul}
}