Abstract
The report compares the characteristics of three period meter circuits: - a linear circuit - a circuit which is non-linear according to the nuclear reactor period - a circuit which is non-linear according to the period and the power of the reactor. This last type of reactor has a fast time of response if the power is high or if the period is short, and it has a slow time of response when the power is low and the period long; this system makes it possible to maintain the noise at an acceptable level under all normal working conditions of the reactor. (author) [French] Le rapport compare les caracteristiques de trois circuits de periodemetres: - un circuit lineaire; - un circuit non lineaire selon la periode du reacteur nucleaire; - un circuit non lineaire selon la periode et la puissance du reacteur. Ce dernier type de circuit a un court temps de reponse si la puissance est faible et la periode grande; ce systeme permet de limiter le bruit a des niveaux acceptables dans toutes les conditions normales de fonctionnement du reacteur. (auteur)
Friedling, G
[1]
- Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Citation Formats
Friedling, G.
The noise-time of response compromise in d.c. period meters. A new type of circuit (1961); Le compromis bruit-temps de reponse dans les periodemetres a courant continu. un nouveau type de circuit (1961).
France: N. p.,
1961.
Web.
Friedling, G.
The noise-time of response compromise in d.c. period meters. A new type of circuit (1961); Le compromis bruit-temps de reponse dans les periodemetres a courant continu. un nouveau type de circuit (1961).
France.
Friedling, G.
1961.
"The noise-time of response compromise in d.c. period meters. A new type of circuit (1961); Le compromis bruit-temps de reponse dans les periodemetres a courant continu. un nouveau type de circuit (1961)."
France.
@misc{etde_20740204,
title = {The noise-time of response compromise in d.c. period meters. A new type of circuit (1961); Le compromis bruit-temps de reponse dans les periodemetres a courant continu. un nouveau type de circuit (1961)}
author = {Friedling, G}
abstractNote = {The report compares the characteristics of three period meter circuits: - a linear circuit - a circuit which is non-linear according to the nuclear reactor period - a circuit which is non-linear according to the period and the power of the reactor. This last type of reactor has a fast time of response if the power is high or if the period is short, and it has a slow time of response when the power is low and the period long; this system makes it possible to maintain the noise at an acceptable level under all normal working conditions of the reactor. (author) [French] Le rapport compare les caracteristiques de trois circuits de periodemetres: - un circuit lineaire; - un circuit non lineaire selon la periode du reacteur nucleaire; - un circuit non lineaire selon la periode et la puissance du reacteur. Ce dernier type de circuit a un court temps de reponse si la puissance est faible et la periode grande; ce systeme permet de limiter le bruit a des niveaux acceptables dans toutes les conditions normales de fonctionnement du reacteur. (auteur)}
place = {France}
year = {1961}
month = {Jul}
}
title = {The noise-time of response compromise in d.c. period meters. A new type of circuit (1961); Le compromis bruit-temps de reponse dans les periodemetres a courant continu. un nouveau type de circuit (1961)}
author = {Friedling, G}
abstractNote = {The report compares the characteristics of three period meter circuits: - a linear circuit - a circuit which is non-linear according to the nuclear reactor period - a circuit which is non-linear according to the period and the power of the reactor. This last type of reactor has a fast time of response if the power is high or if the period is short, and it has a slow time of response when the power is low and the period long; this system makes it possible to maintain the noise at an acceptable level under all normal working conditions of the reactor. (author) [French] Le rapport compare les caracteristiques de trois circuits de periodemetres: - un circuit lineaire; - un circuit non lineaire selon la periode du reacteur nucleaire; - un circuit non lineaire selon la periode et la puissance du reacteur. Ce dernier type de circuit a un court temps de reponse si la puissance est faible et la periode grande; ce systeme permet de limiter le bruit a des niveaux acceptables dans toutes les conditions normales de fonctionnement du reacteur. (auteur)}
place = {France}
year = {1961}
month = {Jul}
}