You need JavaScript to view this

Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur

Abstract

This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10{sup -5} channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [French] Cette etude a pour objet la stabilisation des spectres fournis par un spectrometre a rayons gamma. On veut maintenir la droite  More>>
Authors:
Detourne, G [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jun 15, 1967
Product Type:
Thesis/Dissertation
Report Number:
CEA-R-3300
Resource Relation:
Other Information: TH: These sciences; 33 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CALIBRATION; CLOSED-LOOP CONTROL; COMPARATOR CIRCUITS; CORRECTIONS; DIGITAL-TO-ANALOG CONVERTERS; ENERGY SPECTRA; FLIP-FLOP CIRCUITS; GAIN; GAMMA SPECTROMETERS; PEAKS; SIGNAL CONDITIONING; STABILIZATION
OSTI ID:
20726936
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France); Faculte des Sciences de l'Universite de Paris, 75 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R3300038381
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
[156] pages
Announcement Date:
May 30, 2006

Citation Formats

Detourne, G. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur. France: N. p., 1967. Web.
Detourne, G. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur. France.
Detourne, G. 1967. "Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur." France.
@misc{etde_20726936,
title = {Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur}
author = {Detourne, G}
abstractNote = {This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10{sup -5} channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [French] Cette etude a pour objet la stabilisation des spectres fournis par un spectrometre a rayons gamma. On veut maintenir la droite d'etalonnage du spectrometre dans une position fixee initialement a mieux de 6.10{sup -5} canal pres. On realise un prototype de stabilisateur numerique, le SPECTROSTAB; il comprend deux boucles d'asservissement independantes; l'une d'elles asservit le gain du spectrometre aux derives d'un pic de reference aux hautes energies; l'autre asservit l'origine de l'echelle des energies aux derives d'un second pic de reference aux basses energies. Une etude theorique du comportement d'une boucle d'asservissement montre qu'un stabilisateur a action directe permet la stabilisation la plus precise; la perte en resolution sur les pics theoriques des spectres atteint environ 1 % avec un detecteur a scintillateur et 10 % avec un detecteur a semi-conducteur. Divers essais montrent qu'on obtient les resultats attendus et que les deplacements des pics des spectres sous l'effet des derives sont masques par les erreurs du calcul des abscisses des pics. (auteur)}
place = {France}
year = {1967}
month = {Jun}
}