You need JavaScript to view this

Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion

Abstract

We have built an apparatus to measure the specific heat of metal up to the melting point. The method is the pulse-heating method, where the specimen is heated very rapidly (1/10 s) from room temperature to the melting point by a very intense d.c. current (1000 A). The simultaneous measurements of intensity, voltage and temperature in the specimen allows a calculation of the specific heat. We have obtained good results for niobium, tungsten, tantalum and uranium. The accuracy is around 3 to 5 per cent and allows a measurement of the heat of formation of vacancies near the melting temperature. (author) [French] Nous avons construit un appareil permettant la mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion. La methode utilisee est la methode dite de chauffage instantane, L'echantillon est echauffe tres rapidement (1/10 s) de la temperature ambiante a la temperature de fusion par le passage d'un courant tres intense ({approx} 1000 A). L'enregistrement simultane de l'intensite du courant, de la difference de potentiel aux bornes de l'echantillon et de la temperature, permet de calculer la chaleur specifique. Nous avons obtenu de bons resultats pour le niobium, le tungstene tantale et l'uranium. La precision de la  More>>
Authors:
Affortit, Ch [1] 
  1. Commissariat a l'Energie Atomique, Fontenay-aux-Roses (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 15, 1967
Product Type:
Thesis/Dissertation
Report Number:
CEA-R-3287
Resource Relation:
Other Information: TH: These; 50 refs
Subject:
36 MATERIALS SCIENCE; CALORIMETERS; FLASH HEATING; JOULE HEATING; MEASURING INSTRUMENTS; MEASURING METHODS; MELTING POINTS; METALS; SPECIFIC HEAT; THERMAL ANALYSIS; THERMAL CONDUCTIVITY
OSTI ID:
20726923
Research Organizations:
CEA Fontenay-aux-Roses, Service des Elements Combustibles au Plutonium et d'Etudes Radiometallurgiques, 92 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR06R3287038368
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
[63] pages
Announcement Date:
May 24, 2006

Citation Formats

Affortit, Ch. Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion. France: N. p., 1967. Web.
Affortit, Ch. Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion. France.
Affortit, Ch. 1967. "Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion." France.
@misc{etde_20726923,
title = {Specific heat measurements on metals up to their melting point; Mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion}
author = {Affortit, Ch}
abstractNote = {We have built an apparatus to measure the specific heat of metal up to the melting point. The method is the pulse-heating method, where the specimen is heated very rapidly (1/10 s) from room temperature to the melting point by a very intense d.c. current (1000 A). The simultaneous measurements of intensity, voltage and temperature in the specimen allows a calculation of the specific heat. We have obtained good results for niobium, tungsten, tantalum and uranium. The accuracy is around 3 to 5 per cent and allows a measurement of the heat of formation of vacancies near the melting temperature. (author) [French] Nous avons construit un appareil permettant la mesure de la chaleur specifique des metaux jusqu'a leur temperature de fusion. La methode utilisee est la methode dite de chauffage instantane, L'echantillon est echauffe tres rapidement (1/10 s) de la temperature ambiante a la temperature de fusion par le passage d'un courant tres intense ({approx} 1000 A). L'enregistrement simultane de l'intensite du courant, de la difference de potentiel aux bornes de l'echantillon et de la temperature, permet de calculer la chaleur specifique. Nous avons obtenu de bons resultats pour le niobium, le tungstene tantale et l'uranium. La precision de la methode est de l'ordre de 3 a 5 pour cent et permet une mesure de la chaleur de formation des lacunes au voisinage de la fusion. (auteur)}
place = {France}
year = {1967}
month = {Jul}
}