Abstract

During the previous period RA reactor was not operated because the Committee of Serbian ministry for health and social care has cancelled the operation licence in August 1984. The reason was the non existing emergency cooling system and lack of appropriate filters in the special ventilation system. The new emergency cooling system and the reconstruction of the existing ventilation system were finished in 1989, the conditions for further reactor operation were fulfilled. In the meantime new licensing regulations adopted in 1988 were not demanding the mentioned conditions for reactors operated at power less than 10MW, RA reactor power being 6.5 MW. But the reactor could not be restarted due to planned renewal of the reactor instrumentation. It is planned to exchange the complete instrumentation by the end of 1991. Training program for the staff operating and maintaining the reactor components was prepared in 1985. Reconstruction, modification and construction of components demanded new documentation needed for further safe reactor operation. New version of RA reactor safety report was finished in 1986 according to the recommendations of IAEA and licensing regulations of Yugoslavia. In 1989, new documents were written covering regulations and instructions for reactor operation. The new reactor experimental loop was  More>>
Authors:
Sotic, O; Cupac, S; Sulem, B; Zivotic, Z; Vasovic, B; Sanovic, V [1] 
  1. Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
Publication Date:
Dec 15, 1990
Product Type:
Technical Report
Report Number:
INIS-CS-0032; RA-103/R1/P2/12/01
Resource Relation:
Other Information: 4 tabs; Related Information: In: Research nuclear reactor RA - Annual Report 1990 with the comparative evaluation for the period 1986-1990, Istrazivacki nuklearni reaktor RA - Izvestaj za 1990. godinu uz uporedni pregled za period 1986 - 1990, by Sotic, O. [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)], 358 pages.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; ECCS; FINANCING; IAEA; LEGAL ASPECTS; LICENSING REGULATIONS; PERSONNEL MANAGEMENT; R-A REACTOR; REACTOR COMPONENTS; REACTOR CONTROL SYSTEMS; REACTOR INSTRUMENTATION; REACTOR LICENSING; REACTOR MAINTENANCE; SAFETY REPORTS; SCHEDULES; VENTILATION SYSTEMS
OSTI ID:
20714191
Research Organizations:
Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
Country of Origin:
Serbia and Montenegro
Language:
English
Other Identifying Numbers:
TRN: CS06RA217028288
Availability:
Available from INIS in electronic form; Also available from the Institute of nuclear sciences Vinca
Submitting Site:
INIS
Size:
page(s) 50
Announcement Date:
May 08, 2006

Citation Formats

Sotic, O, Cupac, S, Sulem, B, Zivotic, Z, Vasovic, B, and Sanovic, V. RA reactor operation and maintenance in 1990 with comparative evaluation from 1986-1990, Part 1; Deo 1 - Pogon i odrzavanje nuklearnog reaktora RA u 1990. godini, uz uporedni pregled za period 1986-1990. godina. Serbia and Montenegro: N. p., 1990. Web.
Sotic, O, Cupac, S, Sulem, B, Zivotic, Z, Vasovic, B, & Sanovic, V. RA reactor operation and maintenance in 1990 with comparative evaluation from 1986-1990, Part 1; Deo 1 - Pogon i odrzavanje nuklearnog reaktora RA u 1990. godini, uz uporedni pregled za period 1986-1990. godina. Serbia and Montenegro.
Sotic, O, Cupac, S, Sulem, B, Zivotic, Z, Vasovic, B, and Sanovic, V. 1990. "RA reactor operation and maintenance in 1990 with comparative evaluation from 1986-1990, Part 1; Deo 1 - Pogon i odrzavanje nuklearnog reaktora RA u 1990. godini, uz uporedni pregled za period 1986-1990. godina." Serbia and Montenegro.
@misc{etde_20714191,
title = {RA reactor operation and maintenance in 1990 with comparative evaluation from 1986-1990, Part 1; Deo 1 - Pogon i odrzavanje nuklearnog reaktora RA u 1990. godini, uz uporedni pregled za period 1986-1990. godina}
author = {Sotic, O, Cupac, S, Sulem, B, Zivotic, Z, Vasovic, B, and Sanovic, V}
abstractNote = {During the previous period RA reactor was not operated because the Committee of Serbian ministry for health and social care has cancelled the operation licence in August 1984. The reason was the non existing emergency cooling system and lack of appropriate filters in the special ventilation system. The new emergency cooling system and the reconstruction of the existing ventilation system were finished in 1989, the conditions for further reactor operation were fulfilled. In the meantime new licensing regulations adopted in 1988 were not demanding the mentioned conditions for reactors operated at power less than 10MW, RA reactor power being 6.5 MW. But the reactor could not be restarted due to planned renewal of the reactor instrumentation. It is planned to exchange the complete instrumentation by the end of 1991. Training program for the staff operating and maintaining the reactor components was prepared in 1985. Reconstruction, modification and construction of components demanded new documentation needed for further safe reactor operation. New version of RA reactor safety report was finished in 1986 according to the recommendations of IAEA and licensing regulations of Yugoslavia. In 1989, new documents were written covering regulations and instructions for reactor operation. The new reactor experimental loop was designed in 1986, and constructed and tested in 1990. All the reactor components were maintained by specific reactor services. Financing of the reactor remains a permanent problem. [Serbo-Croat] U proteklom periodu reaktor RA nije bio u pogonu zato sto je 30. jula 1984. godine Republicki komitet za zdravlje i socijalnu politiku republike Srbije, zabranio njegov rad zbog toga sto reaktor ne poseduje sistem za udesno hladjenje i ne poseduje odgovarajuce filtere u sistemu specijalne ventilacije. Radovi na izgradnji sistema za udesno hladjenje i rekonstrukciji postojeceg sistema specijalne ventilacije zavrseni su 1989. godine. Uslovi za nastavak rada reaktora tako su zadovoljeni a u medjuvremenu je objavljen novi pravilnik po kome se pomenuti uslovi vise ne zahtevaju za reaktore snage manje od 10MW, a snaga reaktora RA je 6,5 MW. Medjutim ranije izdato naredjenje o prekidu rada reaktora nije ukinuto. Reaktor nije poceo sa radom i usled najvece rekonstrukcije, zamene celokupne instrumentacije koja je planirana da traje do kraja 1991. godine. Program obuke radnika koji rade u pogonu i odrzavanje reaktora sacinjen je 1985. godine. Rekonstrukcija, modifikacija i izgradnja novih sistema na reaktoru RA zahtevali su i izradu novih dokumenta za dalji siguran i bezbedan rad reaktora. Nova verzija Sigurnosnog izvestaja reaktora RA zavrsena je 1986. u skladu sa preporukama MAAE i 'Pravilnikom o izradi i sadrzaju izvestaja o sigurnosti i druge dokumentacije potrebne za utvrdjivanje sigurnosti nuklearnih objekata' (objavljenom novembra 1988. godine). U novembru 1989. zavrsena je izrada dokumenta koji sadrzi nove propise i uputstva za rad i eksploataciju reaktora RA. Reaktorska petlja projektovana 1986. izgradjena je i ispitana 1990. Sve reaktorske komponente odrzavale su redovno posebno formirane sluzbe, za instrumentaciju, masinsku i elektroopremu. Nedovoljna sredstva za pogon i odrzavanje opreme reaktora RA predstavljaju veliki problem za uspesno i efikasno obavljanje poslova.}
place = {Serbia and Montenegro}
year = {1990}
month = {Dec}
}