Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule

Abstract

Fluctuations in the time response of photomultipliers employed in scintillation counting are studied and experimentally checked. Statistical measurements of the output pulses show that the relative variance of the time fluctuations is minimum for the portion located around the bending point of the leading edge. A shaping circuit using this property is described. Experimental results are given, showing an improvement of the resolving time. (author) [French] Les fluctuations de la reponse temporelle des photomultiplicateurs, utilises dans les detecteurs a scintillations, sont etudiees et mesurees experimentalement. L'etude statistique des signaux de sortie montre que les fluctuations en temps presentent une variance relative minimale pour la region situee autour du point d'inflexion du front de montee. Un circuit de mise en forme utilisant cette propriete est decrit. Des resultats experimentaux sont donnes; ils montrent une amelioration sensible du pouvoir de resolution. (auteur)
Authors:
Hesse, M [1] 
  1. Commissariat a l'Energie Atomique, Grenoble (France). Centre d'Etudes Nucleaires
Publication Date:
Jun 01, 1965
Product Type:
Thesis/Dissertation
Report Number:
CEA-R-2885
Resource Relation:
Other Information: TH: These sciences; 19 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; FLUCTUATIONS; PHOTOMULTIPLIERS; PULSE GENERATORS; SCINTILLATION COUNTING; TIME RESOLUTION
OSTI ID:
20680290
Research Organizations:
CEA Grenoble, 38 (France); Faculte des Sciences de l'Universite de Lyon, 69 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2885115180
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
62 pages
Announcement Date:
Jan 07, 2006

Citation Formats

Hesse, M. Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule. France: N. p., 1965. Web.
Hesse, M. Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule. France.
Hesse, M. 1965. "Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule." France.
@misc{etde_20680290,
title = {Application of new fast-electronic techniques to the determination of the exact moment of particle detection; Application des techniques nouvelles de l'electronique rapide a la determination de l'instant precis de detection d'une particule}
author = {Hesse, M}
abstractNote = {Fluctuations in the time response of photomultipliers employed in scintillation counting are studied and experimentally checked. Statistical measurements of the output pulses show that the relative variance of the time fluctuations is minimum for the portion located around the bending point of the leading edge. A shaping circuit using this property is described. Experimental results are given, showing an improvement of the resolving time. (author) [French] Les fluctuations de la reponse temporelle des photomultiplicateurs, utilises dans les detecteurs a scintillations, sont etudiees et mesurees experimentalement. L'etude statistique des signaux de sortie montre que les fluctuations en temps presentent une variance relative minimale pour la region situee autour du point d'inflexion du front de montee. Un circuit de mise en forme utilisant cette propriete est decrit. Des resultats experimentaux sont donnes; ils montrent une amelioration sensible du pouvoir de resolution. (auteur)}
place = {France}
year = {1965}
month = {Jun}
}