You need JavaScript to view this

Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion

Abstract

A high temperature apparatus for vapour pressure measurements by Knudsen effusion method is described. Sample is heated in a tungsten cell in an electronic bombardment furnace. Several critical factors affecting the accuracy of measurements such as: - temperature distribution and measurement in the effusion cell, - CLAUSING factor and molecular flow, - compatibility between cell material and sample heated, are discussed with careful attention. Vapour pressure of UO{sub 2} has been studied between 2200 and 2800 K. Experimental points fit a curve expressed by: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) which is in good agreement with previous results of literature. (author) [French] On decrit un appareil destine a la mesure des tensions de vapeur par la methode d'effusion de KNUDSEN. L'echantillon contenu dans une cellule en tungstene est chauffe par bombardement electronique. Apres examen critique des divers facteurs affectant l'exactitude des mesures, a savoir: - homogeneite et mesure de la temperature dans la cellule d'effusion, - facteur de 'CLAUSING' et loi de distribution en cosinus des molecules effusees, - compatibilite a chaud entre le materiau de la cellule et le materiau etudie. On a procede a la mesure de la tension de vapeur de UO{sub 2} qui  More>>
Authors:
Ohse, R W [1] 
  1. Commissariat a l'Energie Atomique, Fontenay-aux-Roses (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1965
Product Type:
Technical Report
Report Number:
CEA-R-2871
Resource Relation:
Other Information: 47 refs
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; ACCURACY; KNUDSEN FLOW; TEMPERATURE DISTRIBUTION; TEMPERATURE RANGE 1000-4000 K; THERMODYNAMIC PROPERTIES; URANIUM DIOXIDE; VAPOR PRESSURE
OSTI ID:
20680276
Research Organizations:
CEA Fontenay-aux-Roses, 92 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2871115166
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
71 pages
Announcement Date:
Jan 07, 2006

Citation Formats

Ohse, R W. Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion. France: N. p., 1965. Web.
Ohse, R W. Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion. France.
Ohse, R W. 1965. "Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion." France.
@misc{etde_20680276,
title = {Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion}
author = {Ohse, R W}
abstractNote = {A high temperature apparatus for vapour pressure measurements by Knudsen effusion method is described. Sample is heated in a tungsten cell in an electronic bombardment furnace. Several critical factors affecting the accuracy of measurements such as: - temperature distribution and measurement in the effusion cell, - CLAUSING factor and molecular flow, - compatibility between cell material and sample heated, are discussed with careful attention. Vapour pressure of UO{sub 2} has been studied between 2200 and 2800 K. Experimental points fit a curve expressed by: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) which is in good agreement with previous results of literature. (author) [French] On decrit un appareil destine a la mesure des tensions de vapeur par la methode d'effusion de KNUDSEN. L'echantillon contenu dans une cellule en tungstene est chauffe par bombardement electronique. Apres examen critique des divers facteurs affectant l'exactitude des mesures, a savoir: - homogeneite et mesure de la temperature dans la cellule d'effusion, - facteur de 'CLAUSING' et loi de distribution en cosinus des molecules effusees, - compatibilite a chaud entre le materiau de la cellule et le materiau etudie. On a procede a la mesure de la tension de vapeur de UO{sub 2} qui est relativement bien connue. Entre 2200 et 2800 K les points experimentaux se placent sur une courbe: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) en bon accord avec les valeurs citees dans la litterature. (auteur)}
place = {France}
year = {1965}
month = {Jul}
}