You need JavaScript to view this

Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles

Abstract

Spark source mass spectrometer MS7 has been designed to determine traces of impurities in solids without standards. An atlas of 12 000 lines, assembled in the Grenoble laboratory, allows a quick investigation of mass spectra, notwithstanding their complexity due to multiply charged and polyatomic darkening. Photometric measurements increase accuracy calibration curve is known for each photo-plate. Further, reproducibility is better, if random fluctuations of matrix line darkening are corrected. So far, in a concentration range of 0,01 to 1 000 ppm (atomic), reproducibility is approximately 20 per cent, but absolute value of results depends on 'sensitivity coefficients'. (authors) [French] Le spectrometre de masse a etincelles, de type MS7, est destine a l'analyse chimique de traces dans les solides, sans echantillons etalons. L'emploi de catalogues de 12 000 raies, elabores au laboratoire, permet un depouillement rapide des spectres, malgre leur complexite due aux ionisations multiples et aux associations d'atomes. Le niveau d'apparition d'une impurete donne une estimation de sa teneur, mais la valeur du renseignement depend de la preparation des electrodes et de la connaissance plus ou moins approfondie des processus d'ionisation dans l'etincelle et de noircissement des emulsions photographiques. Les mesures photometriques augmentent la precision des resultats, si l'on determine  More>>
Authors:
Stefani, R; Desjardins, M; Brun, J C; Cornu, A; Bourguillot, R [1] 
  1. Commissariat a l'Energie Atomique, Grenoble (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1965
Product Type:
Technical Report
Report Number:
CEA-R-2757
Resource Relation:
Other Information: 9 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ACCURACY; FLAT MAGNETIC SPECTROMETERS; IMPURITIES; PERFORMANCE; SENSITIVITY; SPARK MASS SPECTROMETERS; TRACE AMOUNTS
OSTI ID:
20680239
Research Organizations:
CEA Grenoble, 38 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2757115129
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
28 pages
Announcement Date:
Jan 09, 2006

Citation Formats

Stefani, R, Desjardins, M, Brun, J C, Cornu, A, and Bourguillot, R. Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles. France: N. p., 1965. Web.
Stefani, R, Desjardins, M, Brun, J C, Cornu, A, & Bourguillot, R. Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles. France.
Stefani, R, Desjardins, M, Brun, J C, Cornu, A, and Bourguillot, R. 1965. "Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles." France.
@misc{etde_20680239,
title = {Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles}
author = {Stefani, R, Desjardins, M, Brun, J C, Cornu, A, and Bourguillot, R}
abstractNote = {Spark source mass spectrometer MS7 has been designed to determine traces of impurities in solids without standards. An atlas of 12 000 lines, assembled in the Grenoble laboratory, allows a quick investigation of mass spectra, notwithstanding their complexity due to multiply charged and polyatomic darkening. Photometric measurements increase accuracy calibration curve is known for each photo-plate. Further, reproducibility is better, if random fluctuations of matrix line darkening are corrected. So far, in a concentration range of 0,01 to 1 000 ppm (atomic), reproducibility is approximately 20 per cent, but absolute value of results depends on 'sensitivity coefficients'. (authors) [French] Le spectrometre de masse a etincelles, de type MS7, est destine a l'analyse chimique de traces dans les solides, sans echantillons etalons. L'emploi de catalogues de 12 000 raies, elabores au laboratoire, permet un depouillement rapide des spectres, malgre leur complexite due aux ionisations multiples et aux associations d'atomes. Le niveau d'apparition d'une impurete donne une estimation de sa teneur, mais la valeur du renseignement depend de la preparation des electrodes et de la connaissance plus ou moins approfondie des processus d'ionisation dans l'etincelle et de noircissement des emulsions photographiques. Les mesures photometriques augmentent la precision des resultats, si l'on determine systematiquement la courbe de noircissement de chaque plaque. De meme la reproductibilite est amelioree si l'on tient compte des fluctuations statistiques du noircissement de l'emulsion par les ions de la matrice. Actuellement, les concentrations mesurees dans le domaine de 0,01 a 1000 ppm atomiques sont reproductibles a 20 pour cent pres, mais leur valeur absolue n'est assuree qu'a un coefficient 3 pres. Des etudes sont en cours pour calibrer l'appareil en valeur absolue, par une determination des coefficients de sensibilite a partir d'echantillons etalons. (auteurs)}
place = {France}
year = {1965}
month = {Jul}
}