You need JavaScript to view this

Biological monochromator with a high flux in the visible spectrum; Un monochromateur biologique a haut flux dans le visible

Abstract

The object is to carry out research into photosynthesis using energetic illuminations similar to those employed with white light studies. The limitations are due mainly to the source. A comparison of various possible solutions has led to the choice of the sun used in conjunction with 4 large gratings. In an intermediate stage, a description is given of a medium-aperture monochromator with a 3 kW xenon arc and a single grating. With this set-up it is possible to obtain the following performance, given as an example; energy illumination, 1.3 mW/cm{sup 2} over a surface of 50 cm{sup 2} and for a bandwidth at half-height of 50 Angstroms. (authors) [French] L'objectif est de poursuivre en lumiere monochromatique des etudes de photosynthese avec des eclairements energetiques analogues a ceux qu'on utilise en lumiere blanche. Les limitations se situent principalement au niveau de la source. Une comparaison effectuee entre differentes solutions possibles conduit a preconiser l'emploi du soleil associe a 4 grands reseaux. En etape intermediaire on decrit un monochromateur de moyenne ouverture, avec un arc au xenon de 3 kW et un seul reseau, qui permet d'atteindre les performances suivantes donnees a titre d'exemple: eclairement energetique de 1,3 mW/cm{sup 2} sur une  More>>
Authors:
Andre, M; Guerin de Montgareuil, P [1] 
  1. Commissariat a l'Energie Atomique, Cadarache (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1965
Product Type:
Technical Report
Report Number:
CEA-R-2756
Resource Relation:
Other Information: 6 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; BRIGHTNESS; MEASURING METHODS; MONOCHROMATORS; PERFORMANCE; PHOTOSYNTHESIS; VISIBLE SPECTRA
OSTI ID:
20680238
Research Organizations:
CEA Cadarache, 13 - Saint-Paul-lez-Durance (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2756115128
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
20 pages
Announcement Date:
Jan 07, 2006

Citation Formats

Andre, M, and Guerin de Montgareuil, P. Biological monochromator with a high flux in the visible spectrum; Un monochromateur biologique a haut flux dans le visible. France: N. p., 1965. Web.
Andre, M, & Guerin de Montgareuil, P. Biological monochromator with a high flux in the visible spectrum; Un monochromateur biologique a haut flux dans le visible. France.
Andre, M, and Guerin de Montgareuil, P. 1965. "Biological monochromator with a high flux in the visible spectrum; Un monochromateur biologique a haut flux dans le visible." France.
@misc{etde_20680238,
title = {Biological monochromator with a high flux in the visible spectrum; Un monochromateur biologique a haut flux dans le visible}
author = {Andre, M, and Guerin de Montgareuil, P}
abstractNote = {The object is to carry out research into photosynthesis using energetic illuminations similar to those employed with white light studies. The limitations are due mainly to the source. A comparison of various possible solutions has led to the choice of the sun used in conjunction with 4 large gratings. In an intermediate stage, a description is given of a medium-aperture monochromator with a 3 kW xenon arc and a single grating. With this set-up it is possible to obtain the following performance, given as an example; energy illumination, 1.3 mW/cm{sup 2} over a surface of 50 cm{sup 2} and for a bandwidth at half-height of 50 Angstroms. (authors) [French] L'objectif est de poursuivre en lumiere monochromatique des etudes de photosynthese avec des eclairements energetiques analogues a ceux qu'on utilise en lumiere blanche. Les limitations se situent principalement au niveau de la source. Une comparaison effectuee entre differentes solutions possibles conduit a preconiser l'emploi du soleil associe a 4 grands reseaux. En etape intermediaire on decrit un monochromateur de moyenne ouverture, avec un arc au xenon de 3 kW et un seul reseau, qui permet d'atteindre les performances suivantes donnees a titre d'exemple: eclairement energetique de 1,3 mW/cm{sup 2} sur une surface de 50 cm{sup 2} et pour une bande passante a mi-hauteur de 50 Angstroems. (auteurs)}
place = {France}
year = {1965}
month = {Jul}
}