Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}

Abstract

In this paper, the principle of the standardization of the radioisotopes by the 4{pi} {beta} - {gamma} coincidence method is reminded. Some theoretical examples are given emphasizing on instrumental coincidences and their corrections. The experimental apparatus is described: one discusses the choice of the experimental conditions for the many isotopes measured. Results are given and discussed. In appendix we describe the preparation of the sources. (authors) [French] Dans ce rapport, nous rappelons d'abord le principe de la methode d'etalonnage 4{pi} {beta} - {gamma} en donnant quelques exemples theoriques et en insistant sur la correction des erreurs instrumentales. Une description critique de l'appareillage utilise est donnee. On discute le choix des conditions experimentales pour divers isotopes mesures et les resultats obtenus. En annexe, nous decrivons la fabrication des sources que nous mesurons.
Authors:
Benoit, P; Philis, C [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1965
Product Type:
Technical Report
Report Number:
CEA-R-2711
Resource Relation:
Other Information: 22 refs
Subject:
07 ISOTOPES AND RADIATION SOURCES; ABSOLUTE COUNTING; BETA DECAY; BETA DETECTION; BETA SOURCES; CERIUM 141; COBALT 60; COINCIDENCE METHODS; GAMMA SOURCES; GOLD 198; NIOBIUM 95; SCANDIUM 46; THULIUM 170
OSTI ID:
20680211
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2711115101
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
126 pages
Announcement Date:
Jan 09, 2006

Citation Formats

Benoit, P, and Philis, C. Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}. France: N. p., 1965. Web.
Benoit, P, & Philis, C. Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}. France.
Benoit, P, and Philis, C. 1965. "Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}." France.
@misc{etde_20680211,
title = {Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}}
author = {Benoit, P, and Philis, C}
abstractNote = {In this paper, the principle of the standardization of the radioisotopes by the 4{pi} {beta} - {gamma} coincidence method is reminded. Some theoretical examples are given emphasizing on instrumental coincidences and their corrections. The experimental apparatus is described: one discusses the choice of the experimental conditions for the many isotopes measured. Results are given and discussed. In appendix we describe the preparation of the sources. (authors) [French] Dans ce rapport, nous rappelons d'abord le principe de la methode d'etalonnage 4{pi} {beta} - {gamma} en donnant quelques exemples theoriques et en insistant sur la correction des erreurs instrumentales. Une description critique de l'appareillage utilise est donnee. On discute le choix des conditions experimentales pour divers isotopes mesures et les resultats obtenus. En annexe, nous decrivons la fabrication des sources que nous mesurons.}
place = {France}
year = {1965}
month = {Jul}
}