After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [French] Apres un rappel succinct du role et des principes de la detection de rupture de gaines, l'auteur fait un expose des conditions de fonctionnement et de l'experience tiree de 4 annees d'exploitation de cette installation sur le reacteur G 3. Il signale au passage les modifications apportees a l'installation d'origine, ainsi que les essais effectues, et les experiences en cours.
Authors:
Plisson, J [1] 
  1. CEA Marcoule, Centre de Production de Plutonium, 30 (France)
Publication Date:
Jul 01, 1964
Product Type:
Technical Report
Report Number:
CEA-R-2710
Resource Relation:
Other Information: 5 refs
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; AUTOMATION; FAILED ELEMENT DETECTION; G-3 REACTOR; PERFORMANCE; REACTOR CONTROL SYSTEMS
OSTI ID:
20680210
Research Organizations:
CEA Marcoule, Centre de Production de Plutonium, 30 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2710115100
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
29 pages
Announcement Date:
Jan 07, 2006

Citation Formats

Plisson, J. Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation. France: N. p., 1964. Web.
Plisson, J. Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation. France.
Plisson, J. 1964. "Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation." France.
@misc{etde_20680210,
title = {Clad failure detection in G 3 - operational feedback; Detection de rupture de gaines G 3 - experience d'exploitation}
author = {Plisson, J}
abstractNote = {After briefly reviewing the role and the principles of clad failure detection, the author describes the working conditions and the conclusions reached after 4 years operation of this installation on the reactor G 3. He mentions also the modifications made to the original installation as well as the tests carried out and the experiments under way. (author) [French] Apres un rappel succinct du role et des principes de la detection de rupture de gaines, l'auteur fait un expose des conditions de fonctionnement et de l'experience tiree de 4 annees d'exploitation de cette installation sur le reacteur G 3. Il signale au passage les modifications apportees a l'installation d'origine, ainsi que les essais effectues, et les experiences en cours.}
place = {France}
year = {1964}
month = {Jul}
}