You need JavaScript to view this

The functioning of the reactors G2-G3 at Marcoule and E.D.F. 1; Experience de fonctionnement des reacteurs G2-G3 de Marcoule et enseignements des essais de demarrage du reacteur E.D.F. 1 de Chinon

Abstract

After resuming briefly the characteristics of the installations G2-G3 at Marcoule and EDF 1 at Chinon, the authors review the main aspects of the tests, the starting and the exploitation of these reactors. Among the various points examined, particular emphasis is given to the devices of original nature such as tubular fuel elements, flattening of the neutron flux by stuffing, behaviour of the reactor tanks and the cooling circuits, the blowers, unloading devices, regulation and functioning of the informations. This analysis deals equally with the performances obtained and the difficulties and the various incidents experienced during the initial starting period. Among the more interesting results, the progressive increase in the power of the Marcoule reactors is mentioned, obtained through a better knowledge of the parameters covering the functioning of the reactors such as the distribution of the flux and the temperatures etc... acquired during the course of the exploitation of the reactor. The conclusion reached by the authors is that the experience gained on these installations has shown: - that during an initial period, adjustments became necessary, all of which turned out to be possible, - that an analysis of their functioning has permitted the progressive movement towards a truly  More>>
Authors:
Boussard, R; Conte, F; [1]  Stolz, J M [2] 
  1. Commissariat a l'Energie Atomique, Fontenay-aux-Roses (France). Centre d'Etudes Nucleaires
  2. Electricite de France (EDF), 75 - Paris (France)
Publication Date:
Jul 01, 1964
Product Type:
Technical Report
Report Number:
CEA-R-2694
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; ANNULAR FUEL ELEMENTS; BLOWERS; CHINON-1 REACTOR; FAILED ELEMENT DETECTION; G-2 REACTOR; G-3 REACTOR; MECHANICAL VIBRATIONS; NEUTRON FLUX FLATTENING; PRESTRESSED CONCRETE; REACTOR CHARGING MACHINES; REACTOR COOLING SYSTEMS; REACTOR OPERATION; STRESS CORROSION; TEMPERATURE DISTRIBUTION; TEMPERATURE MONITORING; TURBINE BLADES
OSTI ID:
20669823
Research Organizations:
CEA Marcoule, Centre de Production de Plutonium, 30 (France); CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R2694108680
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
22 pages
Announcement Date:
Dec 19, 2005

Citation Formats

Boussard, R, Conte, F, and Stolz, J M. The functioning of the reactors G2-G3 at Marcoule and E.D.F. 1; Experience de fonctionnement des reacteurs G2-G3 de Marcoule et enseignements des essais de demarrage du reacteur E.D.F. 1 de Chinon. France: N. p., 1964. Web.
Boussard, R, Conte, F, & Stolz, J M. The functioning of the reactors G2-G3 at Marcoule and E.D.F. 1; Experience de fonctionnement des reacteurs G2-G3 de Marcoule et enseignements des essais de demarrage du reacteur E.D.F. 1 de Chinon. France.
Boussard, R, Conte, F, and Stolz, J M. 1964. "The functioning of the reactors G2-G3 at Marcoule and E.D.F. 1; Experience de fonctionnement des reacteurs G2-G3 de Marcoule et enseignements des essais de demarrage du reacteur E.D.F. 1 de Chinon." France.
@misc{etde_20669823,
title = {The functioning of the reactors G2-G3 at Marcoule and E.D.F. 1; Experience de fonctionnement des reacteurs G2-G3 de Marcoule et enseignements des essais de demarrage du reacteur E.D.F. 1 de Chinon}
author = {Boussard, R, Conte, F, and Stolz, J M}
abstractNote = {After resuming briefly the characteristics of the installations G2-G3 at Marcoule and EDF 1 at Chinon, the authors review the main aspects of the tests, the starting and the exploitation of these reactors. Among the various points examined, particular emphasis is given to the devices of original nature such as tubular fuel elements, flattening of the neutron flux by stuffing, behaviour of the reactor tanks and the cooling circuits, the blowers, unloading devices, regulation and functioning of the informations. This analysis deals equally with the performances obtained and the difficulties and the various incidents experienced during the initial starting period. Among the more interesting results, the progressive increase in the power of the Marcoule reactors is mentioned, obtained through a better knowledge of the parameters covering the functioning of the reactors such as the distribution of the flux and the temperatures etc... acquired during the course of the exploitation of the reactor. The conclusion reached by the authors is that the experience gained on these installations has shown: - that during an initial period, adjustments became necessary, all of which turned out to be possible, - that an analysis of their functioning has permitted the progressive movement towards a truly industrial exploitation. (authors) [French] Les auteurs, apres un bref rappel des caracteristiques des installations G2 - G3 de MARCOULE et E.D.F. 1 de CHINON, passent en revue les principaux aspects des essais, de la mise en service et de l'exploitation de ces centrales. Parmi les divers points examines, une attention speciale est accordee aux dispositifs presentant un caractere original tels que elements combustibles tubulaires, aplatissement du flux neutronique par gavage, comportement des caissons des reacteurs et des circuits de refroidissement, soufflantes, appareils de dechargement, regulation et fonctionnement des informations. L'analyse presentee porte tant sur les performances obtenues que sur les difficultes et incidents divers qui ont marque la periode initiale de mise en service. Parmi les resultats les plus interessants, l'on cite l'accroissement progressif de la puissance des reacteurs de MARCOULE obtenu grace a la meilleure connaissance acquise en cours d'exploitation des parametres de fonctionnement: repartition du flux et des temperatures par exemple. Les auteurs concluent que l'experience obtenue sur ces installations a montre: - que dans une premiere periode, elles ont necessite des mises au point qui se sont toutes revelees possibles, - que l'analyse de leur fonctionnement a permis d'arriver progressivement a une exploitation veritablement industrielle. (auteurs)}
place = {France}
year = {1964}