You need JavaScript to view this

Transcatheter closure of patent ductus arteriosus using the angled duct occluder

Journal Article:

Abstract

Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 {+-} 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)
Authors:
Yongwen, Qin; Xianxian, Zhao; Hong, Wu; Xing, Zheng; Jijun, Ding; Jianqiang, Hu [1] 
  1. Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology
Publication Date:
Apr 01, 2004
Product Type:
Journal Article
Resource Relation:
Journal Name: Journal of Interventional Radiology; Journal Volume: 13; Journal Issue: 2; Other Information: 1 fig., 4 refs
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; AORTA; ARTERIES; BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; HEART; IMPLANTS; MEDICAL SURVEILLANCE; SURGERY; ULTRASONOGRAPHY
OSTI ID:
20665559
Country of Origin:
China
Language:
Chinese
Other Identifying Numbers:
Journal ID: ISSN 1008-794X; TRN: CN0502412103547
Submitting Site:
INIS
Size:
page(s) 114-116
Announcement Date:
Dec 08, 2005

Journal Article:

Citation Formats

Yongwen, Qin, Xianxian, Zhao, Hong, Wu, Xing, Zheng, Jijun, Ding, and Jianqiang, Hu. Transcatheter closure of patent ductus arteriosus using the angled duct occluder. China: N. p., 2004. Web.
Yongwen, Qin, Xianxian, Zhao, Hong, Wu, Xing, Zheng, Jijun, Ding, & Jianqiang, Hu. Transcatheter closure of patent ductus arteriosus using the angled duct occluder. China.
Yongwen, Qin, Xianxian, Zhao, Hong, Wu, Xing, Zheng, Jijun, Ding, and Jianqiang, Hu. 2004. "Transcatheter closure of patent ductus arteriosus using the angled duct occluder." China.
@misc{etde_20665559,
title = {Transcatheter closure of patent ductus arteriosus using the angled duct occluder}
author = {Yongwen, Qin, Xianxian, Zhao, Hong, Wu, Xing, Zheng, Jijun, Ding, and Jianqiang, Hu}
abstractNote = {Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 {+-} 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)}
journal = {Journal of Interventional Radiology}
issue = {2}
volume = {13}
place = {China}
year = {2004}
month = {Apr}
}