You need JavaScript to view this

Theory, analysis and applications of the operation of the superconducting transformer supplying a direct current to a non-dissipative superconducting charge circuit; Theorie, analyse et applications du fonctionnement du transformateur supraconducteur alimentant en courant continu un circuit de charge supraconducteur non dissipatif

Abstract

The author derives the very simple equations governing the operation of a transformer with superconducting windings supplying direct current to a non-dissipative superconducting charge circuit. An analysis of the various possible modes of operation with direct or slowly varying current raises the problem of the magnetic core. The study. leads to a conclusion which a priori might be surprising: the elimination of the magnetic core and the use of a primary super-conductor. An example of a possible realization of such a transformer is given as an indication, and the present prospects for different applications are considered. (author) [French] L'auteur etablit les equations tres simples de fonctionnement du transformateur a enroulements supraconducteurs alimentant en courant continu un circuit de charge supraconducteur non dissipatif. L'analyse de divers modes de fonctionnement possibles en courant continu ou lentement variable souleve le probleme du noyau magnetique. L'etude aboutit a une conclusion qui a priori aurait pu surprendre: l'elimination du noyau magnetique et l'utilisation d'un primaire supraconducteur. Un exemple de realisation possible d'un tel transformateur est donne a titre indicatif et les perspectives d'applications actuelles sont envisagees. (auteur)
Authors:
Sole, J [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1967
Product Type:
Technical Report
Report Number:
CEA-R-3242
Resource Relation:
Other Information: 9 refs
Subject:
75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY; CRITICAL FIELD; DIRECT CURRENT; MAGNETIC CORES; SUPERCONDUCTORS; TRANSFORMERS
OSTI ID:
20653432
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R3242093017
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
[21] pages
Announcement Date:
Nov 23, 2005

Citation Formats

Sole, J. Theory, analysis and applications of the operation of the superconducting transformer supplying a direct current to a non-dissipative superconducting charge circuit; Theorie, analyse et applications du fonctionnement du transformateur supraconducteur alimentant en courant continu un circuit de charge supraconducteur non dissipatif. France: N. p., 1967. Web.
Sole, J. Theory, analysis and applications of the operation of the superconducting transformer supplying a direct current to a non-dissipative superconducting charge circuit; Theorie, analyse et applications du fonctionnement du transformateur supraconducteur alimentant en courant continu un circuit de charge supraconducteur non dissipatif. France.
Sole, J. 1967. "Theory, analysis and applications of the operation of the superconducting transformer supplying a direct current to a non-dissipative superconducting charge circuit; Theorie, analyse et applications du fonctionnement du transformateur supraconducteur alimentant en courant continu un circuit de charge supraconducteur non dissipatif." France.
@misc{etde_20653432,
title = {Theory, analysis and applications of the operation of the superconducting transformer supplying a direct current to a non-dissipative superconducting charge circuit; Theorie, analyse et applications du fonctionnement du transformateur supraconducteur alimentant en courant continu un circuit de charge supraconducteur non dissipatif}
author = {Sole, J}
abstractNote = {The author derives the very simple equations governing the operation of a transformer with superconducting windings supplying direct current to a non-dissipative superconducting charge circuit. An analysis of the various possible modes of operation with direct or slowly varying current raises the problem of the magnetic core. The study. leads to a conclusion which a priori might be surprising: the elimination of the magnetic core and the use of a primary super-conductor. An example of a possible realization of such a transformer is given as an indication, and the present prospects for different applications are considered. (author) [French] L'auteur etablit les equations tres simples de fonctionnement du transformateur a enroulements supraconducteurs alimentant en courant continu un circuit de charge supraconducteur non dissipatif. L'analyse de divers modes de fonctionnement possibles en courant continu ou lentement variable souleve le probleme du noyau magnetique. L'etude aboutit a une conclusion qui a priori aurait pu surprendre: l'elimination du noyau magnetique et l'utilisation d'un primaire supraconducteur. Un exemple de realisation possible d'un tel transformateur est donne a titre indicatif et les perspectives d'applications actuelles sont envisagees. (auteur)}
place = {France}
year = {1967}
month = {Jul}
}