Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs

Abstract

The instantaneous value of the counting rate of the pulses given by a fission detector settled in a reactor follows the neutron flux, but it is shown that the counter adds a white noise to the measured signal. This report deals with some possibilities of on line numerical handling afforded by this kind of signals. One considers first the influence of a by N numerical divider and one shows that, acting like a quantifier, it adds to the signal a white noise with the power N{sup 2}/{sub 12}. One, studies afterwards the principle of a digital filter aimed to Fourier analyse the signal. The realization of this device is described. It can be used in transfer function measurements at frequencies below 125 kHz. Some examples of experiments performed with this apparatus are presented. One discusses finally the design, according to the same principle, of a power spectral density analyser in the frequency range 0,01 - 10 000 Hz for random signal of the same kind. (author) [French] La valeur instantanee de la frequence de recurrence des impulsions issues d'un detecteur a fission place dans un reacteur est proportionnelle au flux neutronique. Apres avoir montre que le detecteur ajoute un bruit  More>>
Authors:
Le Tilly, Y [1] 
  1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Dec 01, 1966
Product Type:
Thesis/Dissertation
Report Number:
CEA-R-3241
Resource Relation:
Other Information: 13 refs
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; COUNTING RATES; FAST FISSION; FISSION CHAMBERS; FOURIER ANALYSIS; NEUTRON DETECTION; NEUTRON FLUX; SIGNAL CONDITIONING; SPECTRAL DENSITY; THERMAL NEUTRONS; TRANSFER FUNCTIONS
OSTI ID:
20653431
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France); Faculte des Sciences de l'Universite de Paris, 75 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR05R3241093016
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
84 pages
Announcement Date:
Nov 28, 2005

Citation Formats

Le Tilly, Y. Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs. France: N. p., 1966. Web.
Le Tilly, Y. Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs. France.
Le Tilly, Y. 1966. "Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs." France.
@misc{etde_20653431,
title = {Study of problems arising from the use of thermal neutron detectors in a pulsed regime. Application to the development of a digital transferometer adapted to receive signals from these detectors; Etude des problemes poses par l'utilisation des detecteurs de neutrons thermiques fonctionnant en regime impulsionnel. Application a la realisation d'un transferometre numerique adapte aux signaux fournis par ces detecteurs}
author = {Le Tilly, Y}
abstractNote = {The instantaneous value of the counting rate of the pulses given by a fission detector settled in a reactor follows the neutron flux, but it is shown that the counter adds a white noise to the measured signal. This report deals with some possibilities of on line numerical handling afforded by this kind of signals. One considers first the influence of a by N numerical divider and one shows that, acting like a quantifier, it adds to the signal a white noise with the power N{sup 2}/{sub 12}. One, studies afterwards the principle of a digital filter aimed to Fourier analyse the signal. The realization of this device is described. It can be used in transfer function measurements at frequencies below 125 kHz. Some examples of experiments performed with this apparatus are presented. One discusses finally the design, according to the same principle, of a power spectral density analyser in the frequency range 0,01 - 10 000 Hz for random signal of the same kind. (author) [French] La valeur instantanee de la frequence de recurrence des impulsions issues d'un detecteur a fission place dans un reacteur est proportionnelle au flux neutronique. Apres avoir montre que le detecteur ajoute un bruit blanc au signal mesure, on etudie clans ce rapport certaines possibilites de traitement numerique en temps reel offertes par ce type de signaux. On examine d'abord l'influence d'un diviseur numerique par N, et l'on montre que son action, semblable a une quantification, ajoute au signal un bruit blanc de puissance N{sup 2}/{sub 12}. On, etudie ensuite le principe d'un filtre numerique destine a effectuer l'analyse de Fourier du signal, et l'on decrit la realisation de cet appareil qui peut etre utilise pour mesurer des fonctions de transfert a une frequence quelconque inferieure a 10 kHz. Des exemples de mesures faites avec cet appareil sont presentes. On discute enfin la possibilite de realiser suivant le meme principe un analyseur de densite spectrale dans la bande de frequence 0,01 Hz - 10 kHz pour des signeaux aleatoirs representes egalement par la frequence de recurrence d'une suite d'impulsions. (auteur)}
place = {France}
year = {1966}
month = {Dec}
}