Abstract
After reviewing the radio-toxicology of plutonium 239 and conventional detection methods using its {alpha}-radiation, the author considers the measurement of the X emission spectrum of plutonium 239 using a proportional counter filled with argon under pressure. This preliminary work leads to the third part of this research involving the detailed study of the possibilities of applying thin alkali halide crystal scintillators to the detection of soft plutonium X-rays; there follows a systematic study of all the parameters liable to render the detection as sensitive as possible: movement due to the photomultiplier itself and its accessory electronic equipment, nature and size of the crystal scintillator as well as its mode of preparation, shielding against external parasitic radiation. Examples of some applications to the measurement of contamination in humans give an idea of the sensitivity of this method. (author) [French] Apres un apercu de la radiotoxicologie du plutonium 239 et des methodes classiques de detection par son rayonnement {alpha}, on etudie le spectre d'emission X du plutonium 239 avec un compteur proportionnel rempli avec de l'argon sous pression. Ce travail preliminaire permet d'aborder la troisieme partie de cette etude dans laquelle nous examinons d'une fagon approfondie les possibilites d'application des cristaux scintillateurs
More>>
Trouble, Michel
[1]
- Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
Citation Formats
Trouble, Michel.
X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme.
France: N. p.,
1967.
Web.
Trouble, Michel.
X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme.
France.
Trouble, Michel.
1967.
"X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme."
France.
@misc{etde_20622024,
title = {X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme}
author = {Trouble, Michel}
abstractNote = {After reviewing the radio-toxicology of plutonium 239 and conventional detection methods using its {alpha}-radiation, the author considers the measurement of the X emission spectrum of plutonium 239 using a proportional counter filled with argon under pressure. This preliminary work leads to the third part of this research involving the detailed study of the possibilities of applying thin alkali halide crystal scintillators to the detection of soft plutonium X-rays; there follows a systematic study of all the parameters liable to render the detection as sensitive as possible: movement due to the photomultiplier itself and its accessory electronic equipment, nature and size of the crystal scintillator as well as its mode of preparation, shielding against external parasitic radiation. Examples of some applications to the measurement of contamination in humans give an idea of the sensitivity of this method. (author) [French] Apres un apercu de la radiotoxicologie du plutonium 239 et des methodes classiques de detection par son rayonnement {alpha}, on etudie le spectre d'emission X du plutonium 239 avec un compteur proportionnel rempli avec de l'argon sous pression. Ce travail preliminaire permet d'aborder la troisieme partie de cette etude dans laquelle nous examinons d'une fagon approfondie les possibilites d'application des cristaux scintillateurs minces d'halogenure alcalin a la detection du rayonnement X mou du plutonium; suit une etude systematique de tous les parametres susceptibles de rendre la detection aussi sensible que possible: mouvement propre du photomultiplicateur et de l'electronique associee, nature et dimensions du cristal scintillateur ainsi que son mode de fabrication, blindage contre les rayonnements parasites exterieurs. Quelques applications a la mesure des contaminations sur l'homme permettent d'apprecier la sensibilite de cette methode. (auteur)}
place = {France}
year = {1967}
month = {Jul}
}
title = {X-spectrographic method for plutonium detection. Application to contamination measurements in humans; Etude d'une methode de detection du plutonium par spectrographie X. Application a la mesure des contaminations sur l'homme}
author = {Trouble, Michel}
abstractNote = {After reviewing the radio-toxicology of plutonium 239 and conventional detection methods using its {alpha}-radiation, the author considers the measurement of the X emission spectrum of plutonium 239 using a proportional counter filled with argon under pressure. This preliminary work leads to the third part of this research involving the detailed study of the possibilities of applying thin alkali halide crystal scintillators to the detection of soft plutonium X-rays; there follows a systematic study of all the parameters liable to render the detection as sensitive as possible: movement due to the photomultiplier itself and its accessory electronic equipment, nature and size of the crystal scintillator as well as its mode of preparation, shielding against external parasitic radiation. Examples of some applications to the measurement of contamination in humans give an idea of the sensitivity of this method. (author) [French] Apres un apercu de la radiotoxicologie du plutonium 239 et des methodes classiques de detection par son rayonnement {alpha}, on etudie le spectre d'emission X du plutonium 239 avec un compteur proportionnel rempli avec de l'argon sous pression. Ce travail preliminaire permet d'aborder la troisieme partie de cette etude dans laquelle nous examinons d'une fagon approfondie les possibilites d'application des cristaux scintillateurs minces d'halogenure alcalin a la detection du rayonnement X mou du plutonium; suit une etude systematique de tous les parametres susceptibles de rendre la detection aussi sensible que possible: mouvement propre du photomultiplicateur et de l'electronique associee, nature et dimensions du cristal scintillateur ainsi que son mode de fabrication, blindage contre les rayonnements parasites exterieurs. Quelques applications a la mesure des contaminations sur l'homme permettent d'apprecier la sensibilite de cette methode. (auteur)}
place = {France}
year = {1967}
month = {Jul}
}