Abstract
The ablation efficiency of a channel spark system is mainly influenced by its trigger plasma source. Compared to the application of a sliding discharge trigger plasma source a channel spark system triggered by a Penning discharge exhibits high rates of ablated bulk material per shot, a high reproducibility of the ablated mass per shot and an increased lifetime.
Frey, Wolfgang;
Schultheiss, Christoph;
Bluhm, Hansjoachim
[1]
- Forschungszentrum Karlsruhe, Institut fuer Hochleistungsimpuls- und Mikrowellentechnik, P. O. Box 3640, D-76021 Karlsruhe (Germany)
Citation Formats
Frey, Wolfgang, Schultheiss, Christoph, and Bluhm, Hansjoachim.
A new trigger device for channel spark systems based on a Penning discharge.
United States: N. p.,
2002.
Web.
doi:10.1063/1.1530808.
Frey, Wolfgang, Schultheiss, Christoph, & Bluhm, Hansjoachim.
A new trigger device for channel spark systems based on a Penning discharge.
United States.
https://doi.org/10.1063/1.1530808
Frey, Wolfgang, Schultheiss, Christoph, and Bluhm, Hansjoachim.
2002.
"A new trigger device for channel spark systems based on a Penning discharge."
United States.
https://doi.org/10.1063/1.1530808.
@misc{etde_20621302,
title = {A new trigger device for channel spark systems based on a Penning discharge}
author = {Frey, Wolfgang, Schultheiss, Christoph, and Bluhm, Hansjoachim}
abstractNote = {The ablation efficiency of a channel spark system is mainly influenced by its trigger plasma source. Compared to the application of a sliding discharge trigger plasma source a channel spark system triggered by a Penning discharge exhibits high rates of ablated bulk material per shot, a high reproducibility of the ablated mass per shot and an increased lifetime.}
doi = {10.1063/1.1530808}
journal = []
issue = {1}
volume = {650}
journal type = {AC}
place = {United States}
year = {2002}
month = {Dec}
}
title = {A new trigger device for channel spark systems based on a Penning discharge}
author = {Frey, Wolfgang, Schultheiss, Christoph, and Bluhm, Hansjoachim}
abstractNote = {The ablation efficiency of a channel spark system is mainly influenced by its trigger plasma source. Compared to the application of a sliding discharge trigger plasma source a channel spark system triggered by a Penning discharge exhibits high rates of ablated bulk material per shot, a high reproducibility of the ablated mass per shot and an increased lifetime.}
doi = {10.1063/1.1530808}
journal = []
issue = {1}
volume = {650}
journal type = {AC}
place = {United States}
year = {2002}
month = {Dec}
}