Abstract
Commercial transparent and colored (bronze, brown, and green) glasses were studied as possible dosimeters for high gamma doses using electronic paramagnetic resonance (EPR). All EPR spectra showed the characteristic Fe{sup 3+} signals, g=4.27 and 2.01. The signal at g=2.01 presented a more useable behavior for the calibration curve. All samples showed their usefulness as high dose dosimeters.
Teixeira, Maria Ines;
[1]
Ferraz, Gilberto M;
[2]
Caldas, Linda V.E.
[1]
- Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Rua Prof. Lineu Prestes, 2242 05508-900, Sao Paulo (Brazil)
- Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil) and Faculdade de Tecnologia e Ciencias Exatas, Universidade Sao Judas Tadeu, Sao Paulo (Brazil)
Citation Formats
Teixeira, Maria Ines, Ferraz, Gilberto M, and Caldas, Linda V.E.
EPR dosimetry using commercial glasses for high gamma doses.
United Kingdom: N. p.,
2005.
Web.
doi:10.1016/j.apradiso.2004.08.012.
Teixeira, Maria Ines, Ferraz, Gilberto M, & Caldas, Linda V.E.
EPR dosimetry using commercial glasses for high gamma doses.
United Kingdom.
https://doi.org/10.1016/j.apradiso.2004.08.012
Teixeira, Maria Ines, Ferraz, Gilberto M, and Caldas, Linda V.E.
2005.
"EPR dosimetry using commercial glasses for high gamma doses."
United Kingdom.
https://doi.org/10.1016/j.apradiso.2004.08.012.
@misc{etde_20620185,
title = {EPR dosimetry using commercial glasses for high gamma doses}
author = {Teixeira, Maria Ines, Ferraz, Gilberto M, and Caldas, Linda V.E.}
abstractNote = {Commercial transparent and colored (bronze, brown, and green) glasses were studied as possible dosimeters for high gamma doses using electronic paramagnetic resonance (EPR). All EPR spectra showed the characteristic Fe{sup 3+} signals, g=4.27 and 2.01. The signal at g=2.01 presented a more useable behavior for the calibration curve. All samples showed their usefulness as high dose dosimeters.}
doi = {10.1016/j.apradiso.2004.08.012}
journal = []
issue = {2}
volume = {62}
journal type = {AC}
place = {United Kingdom}
year = {2005}
month = {Feb}
}
title = {EPR dosimetry using commercial glasses for high gamma doses}
author = {Teixeira, Maria Ines, Ferraz, Gilberto M, and Caldas, Linda V.E.}
abstractNote = {Commercial transparent and colored (bronze, brown, and green) glasses were studied as possible dosimeters for high gamma doses using electronic paramagnetic resonance (EPR). All EPR spectra showed the characteristic Fe{sup 3+} signals, g=4.27 and 2.01. The signal at g=2.01 presented a more useable behavior for the calibration curve. All samples showed their usefulness as high dose dosimeters.}
doi = {10.1016/j.apradiso.2004.08.012}
journal = []
issue = {2}
volume = {62}
journal type = {AC}
place = {United Kingdom}
year = {2005}
month = {Feb}
}