You need JavaScript to view this

Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection

Abstract

Full text: One technique of improving the sensitivity of interferometric gravitational wave detectors is to implement a signal mirror. This involves placing a mirror at the output of the Michelson interferometer. The gravitational wave signal is then 'recycled' back into the interferometer where it can coherently add with the gravitational wave signal still being produced. The frequency of the improved sensitivity is dependent on the position of the signal mirror, while the peak height and bandwidth are dependent on the reflectivity of the signal mirror. This is because the signal mirror forms a cavity with the Michelson interferometer and this cavity has a resonant frequency dependent on its length and a bandwidth dependent on its finesse, which are a function of signal mirror position and reflectivity, respectively. Due to the varying and/or unknown nature of the gravitational wave frequencies and wave-forms, it is desirable to be able to control both the peak frequency and bandwidth of the detector. The peak frequency can be easily adjusted by altering the signal mirror position. The bandwidth, however, is fixed with the signal mirror reflectivity. In a long base-line gravitational wave detector it is impractical to swap the signal mirror with one of different  More>>
Authors:
De Vine, G; Shaddock, D; McClelland, D [1] 
  1. Australian National University, ACT (Australia)
Publication Date:
Jul 01, 2002
Product Type:
Conference
Resource Relation:
Conference: 15. Biennial Congress of the Australian Institute of Physics. Physics and industry working together, Sydney, NSW (Australia), 8-11 Jul 2002; Other Information: PBD: 2002; Related Information: In: 15th Biennial Congress of the Australian Institute of Physics incorporating Australian Conference of Optical Fibre Technology (ACOFT) and Australian Optical Society (AOS). Handbook and abstracts, 235 pages.
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; COMPARATIVE EVALUATIONS; FABRY-PEROT INTERFEROMETER; FREQUENCY DEPENDENCE; GRAVITATIONAL WAVE DETECTORS; GRAVITATIONAL WAVES; MICHELSON INTERFEROMETER; MIRRORS; REFLECTIVITY; SENSITIVITY; SIGNALS; TUNING; WAVE FORMS
OSTI ID:
20619820
Research Organizations:
Australian Institute of Physics (Australia)
Country of Origin:
Australia
Language:
English
Other Identifying Numbers:
TRN: AU0524498063470
Availability:
Available in abstract form only, full text entered in this record
Submitting Site:
INIS
Size:
page(s) 113
Announcement Date:
Aug 28, 2005

Citation Formats

De Vine, G, Shaddock, D, and McClelland, D. Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection. Australia: N. p., 2002. Web.
De Vine, G, Shaddock, D, & McClelland, D. Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection. Australia.
De Vine, G, Shaddock, D, and McClelland, D. 2002. "Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection." Australia.
@misc{etde_20619820,
title = {Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection}
author = {De Vine, G, Shaddock, D, and McClelland, D}
abstractNote = {Full text: One technique of improving the sensitivity of interferometric gravitational wave detectors is to implement a signal mirror. This involves placing a mirror at the output of the Michelson interferometer. The gravitational wave signal is then 'recycled' back into the interferometer where it can coherently add with the gravitational wave signal still being produced. The frequency of the improved sensitivity is dependent on the position of the signal mirror, while the peak height and bandwidth are dependent on the reflectivity of the signal mirror. This is because the signal mirror forms a cavity with the Michelson interferometer and this cavity has a resonant frequency dependent on its length and a bandwidth dependent on its finesse, which are a function of signal mirror position and reflectivity, respectively. Due to the varying and/or unknown nature of the gravitational wave frequencies and wave-forms, it is desirable to be able to control both the peak frequency and bandwidth of the detector. The peak frequency can be easily adjusted by altering the signal mirror position. The bandwidth, however, is fixed with the signal mirror reflectivity. In a long base-line gravitational wave detector it is impractical to swap the signal mirror with one of different reflectivity for a number of reasons, for example, the detector's high vacuum would have to be broken, realignment performed and locking re-acquired. This is addressed by the proposal of two different forms of variable reflectivity signal mirror (VRSM): a Fabry-Perot cavity and a Michelson interferometer. These are analysed and the reasons for choosing to investigate the Michelson VRSM are given. The reasons include the potential for easier control and the smooth variation in reflectivity with arm length difference. The experiment is discussed and the results of the first demonstration of variable reflectivity signal recycling are presented in the form of frequency responses obtained by injecting a second laser into the back of one of the main Michelson interferometer arm mirrors. This technique mimics the effect of a gravitational wave and by tuning the frequency of this laser the interferometer's frequency response can be mapped out with a spectrum analyser. Frequency responses demonstrating both peak frequency detuning and variable bandwidth are presented.}
place = {Australia}
year = {2002}
month = {Jul}
}