You need JavaScript to view this

Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees

Abstract

This installation has been designed and built for producing sealed sources of fission elements: caesium 137, strontium 90, promethium 147, ruthenium 106 and cerium 144 in particular. The installation consists of sealed and protected cells, each being assigned to a particular production. The safety and the operational reliability of the equipment are the principal considerations which have governed this work. The report describes the installation and, in particular, the apparatus used as well as the various control devices. In conclusion, a review as presented of six years operation. (authors) [French] Cette installation a ete concue et realisee pour effectuer des fabrications de sources scellees d'elements de fission: caesium 137 - strontium 90 - promethium 147 - ruthenium 106 - cerium 144 en particulier. L'installation est composee de cellules etanches et protegees, chacune d'elles etant affectee a une fabrication particuliere. La securite et la surete de fonctionnement de l'ensemble sont parmi les elements principaux qui ont guide l'etude. Le rapport decrit l'installation et plus particulierement l'appareillage utilise ainsi que les divers controles et commandes. Le bilan de fonctionnement apres 6 ans d'exploitation sert de conclusion. (auteurs)
Authors:
Fradin, J; Hayoun, C [1] 
  1. Commissariat a l'Energie Atomique, 91 - Saclay (France). Centre d'Etudes Nucleaires
Publication Date:
Jul 01, 1969
Product Type:
Technical Report
Report Number:
CEA-R-3622
Resource Relation:
Other Information: PBD: 1969
Subject:
07 ISOTOPES AND RADIATION SOURCES; AIRTIGHTNESS; BELT CONVEYORS; CERIUM 144; CESIUM 137; CONTROL SYSTEMS; FABRICATION; GLOVEBOXES; HOT CELLS; MANIPULATORS; NUCLEAR FACILITIES; PELLETIZING; PROMETHIUM 147; RUTHENIUM 106; SAFETY; SEALED SOURCES; SPECIFICATIONS; STRONTIUM 90; VENTILATION SYSTEMS
OSTI ID:
20523405
Research Organizations:
CEA Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR04R3622091460
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
[194] pages
Announcement Date:
Dec 10, 2004

Citation Formats

Fradin, J, and Hayoun, C. Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees. France: N. p., 1969. Web.
Fradin, J, & Hayoun, C. Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees. France.
Fradin, J, and Hayoun, C. 1969. "Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees." France.
@misc{etde_20523405,
title = {Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees}
author = {Fradin, J, and Hayoun, C}
abstractNote = {This installation has been designed and built for producing sealed sources of fission elements: caesium 137, strontium 90, promethium 147, ruthenium 106 and cerium 144 in particular. The installation consists of sealed and protected cells, each being assigned to a particular production. The safety and the operational reliability of the equipment are the principal considerations which have governed this work. The report describes the installation and, in particular, the apparatus used as well as the various control devices. In conclusion, a review as presented of six years operation. (authors) [French] Cette installation a ete concue et realisee pour effectuer des fabrications de sources scellees d'elements de fission: caesium 137 - strontium 90 - promethium 147 - ruthenium 106 - cerium 144 en particulier. L'installation est composee de cellules etanches et protegees, chacune d'elles etant affectee a une fabrication particuliere. La securite et la surete de fonctionnement de l'ensemble sont parmi les elements principaux qui ont guide l'etude. Le rapport decrit l'installation et plus particulierement l'appareillage utilise ainsi que les divers controles et commandes. Le bilan de fonctionnement apres 6 ans d'exploitation sert de conclusion. (auteurs)}
place = {France}
year = {1969}
month = {Jul}
}