Abstract
This report describes a method for controlling the streaming waters produced by the Pierrelatte Centre; it is based on continuous analysis, with simultaneous recording of the species liable to be found accidentally in the corresponding hydrological circuits (chlorides, fluorides, chromium VI, uranium). An alarm set off at pre-determined thresholds leads to an automatic cutting off of the discharge valves; the outward flow of the waters is thus interrupted. This study has shown the various applications which can be found for this water control method, and gives an idea of the cost price. (authors) [French] Ce rapport decrit un mode de controle des eaux de ruissellement provenant du Centre de Pierrelatte base sur une analyse en continu, avec enregistrement des corps susceptibles de se retrouver accidentellement dans les reseaux hydrologiques correspondants (chlorures, fluorures, chrome VI, uranium). Le declenchement d'une alarme a partir de seuils choisis permet de fermer automatiquement les vannes de decharge et d'arreter ainsi l'ecoulement vers l'exterieur. Cette etude montre quelles peuvent etre les diverses applications de cette methode de controle des eaux et elle indique un ordre de grandeur du prix de revient. (auteurs)
Citation Formats
Archimbaud, M, and Simeon, C.
Continuous analytical control of the streaming waters in a uranium treatment plant and of various chemical products using automatic discharge valves; Controle par analyse en continu des eaux de ruissellement d'une usine traitant de l'uranium et divers produits chimiques avec commande automatique des vannes de decharge.
France: N. p.,
1968.
Web.
Archimbaud, M, & Simeon, C.
Continuous analytical control of the streaming waters in a uranium treatment plant and of various chemical products using automatic discharge valves; Controle par analyse en continu des eaux de ruissellement d'une usine traitant de l'uranium et divers produits chimiques avec commande automatique des vannes de decharge.
France.
Archimbaud, M, and Simeon, C.
1968.
"Continuous analytical control of the streaming waters in a uranium treatment plant and of various chemical products using automatic discharge valves; Controle par analyse en continu des eaux de ruissellement d'une usine traitant de l'uranium et divers produits chimiques avec commande automatique des vannes de decharge."
France.
@misc{etde_20523316,
title = {Continuous analytical control of the streaming waters in a uranium treatment plant and of various chemical products using automatic discharge valves; Controle par analyse en continu des eaux de ruissellement d'une usine traitant de l'uranium et divers produits chimiques avec commande automatique des vannes de decharge}
author = {Archimbaud, M, and Simeon, C}
abstractNote = {This report describes a method for controlling the streaming waters produced by the Pierrelatte Centre; it is based on continuous analysis, with simultaneous recording of the species liable to be found accidentally in the corresponding hydrological circuits (chlorides, fluorides, chromium VI, uranium). An alarm set off at pre-determined thresholds leads to an automatic cutting off of the discharge valves; the outward flow of the waters is thus interrupted. This study has shown the various applications which can be found for this water control method, and gives an idea of the cost price. (authors) [French] Ce rapport decrit un mode de controle des eaux de ruissellement provenant du Centre de Pierrelatte base sur une analyse en continu, avec enregistrement des corps susceptibles de se retrouver accidentellement dans les reseaux hydrologiques correspondants (chlorures, fluorures, chrome VI, uranium). Le declenchement d'une alarme a partir de seuils choisis permet de fermer automatiquement les vannes de decharge et d'arreter ainsi l'ecoulement vers l'exterieur. Cette etude montre quelles peuvent etre les diverses applications de cette methode de controle des eaux et elle indique un ordre de grandeur du prix de revient. (auteurs)}
place = {France}
year = {1968}
month = {Jul}
}
title = {Continuous analytical control of the streaming waters in a uranium treatment plant and of various chemical products using automatic discharge valves; Controle par analyse en continu des eaux de ruissellement d'une usine traitant de l'uranium et divers produits chimiques avec commande automatique des vannes de decharge}
author = {Archimbaud, M, and Simeon, C}
abstractNote = {This report describes a method for controlling the streaming waters produced by the Pierrelatte Centre; it is based on continuous analysis, with simultaneous recording of the species liable to be found accidentally in the corresponding hydrological circuits (chlorides, fluorides, chromium VI, uranium). An alarm set off at pre-determined thresholds leads to an automatic cutting off of the discharge valves; the outward flow of the waters is thus interrupted. This study has shown the various applications which can be found for this water control method, and gives an idea of the cost price. (authors) [French] Ce rapport decrit un mode de controle des eaux de ruissellement provenant du Centre de Pierrelatte base sur une analyse en continu, avec enregistrement des corps susceptibles de se retrouver accidentellement dans les reseaux hydrologiques correspondants (chlorures, fluorures, chrome VI, uranium). Le declenchement d'une alarme a partir de seuils choisis permet de fermer automatiquement les vannes de decharge et d'arreter ainsi l'ecoulement vers l'exterieur. Cette etude montre quelles peuvent etre les diverses applications de cette methode de controle des eaux et elle indique un ordre de grandeur du prix de revient. (auteurs)}
place = {France}
year = {1968}
month = {Jul}
}