Regulatory analysis for Generic Issue 23: Reactor coolant pump seal failure. Draft report for comment

Abstract

This report presents the regulatory/backfit analysis for Generic Issue 23 (GI-23), 'Reactor Coolant Pump Seal Failure'. A backfit analysis in accordance with 10 CFR 50.109 is presented in Appendix E. The proposed resolution includes quality assurance provisions for reactor coolant pump seals, instrumentation and procedures for monitoring seal performance, and provisions for seal cooling during off-normal plant conditions involving loss of all seal cooling such as station blackout. Research, technical data, and other analyses supporting the resolution of this issue are summarized in the technical findings report (NUREG/CR-4948) and cost/benefit report (NUREG/CR-5167). (author)
Publication Date:
Apr 01, 1991
Product Type:
Technical Report
Report Number:
NUREG-1401; INIS-XA-N-185
Resource Relation:
Other Information: Refs, figs, tabs; PBD: Apr 1991
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; FAILURES; PUMPS; QUALITY ASSURANCE; REACTOR COOLING SYSTEMS; RISK ASSESSMENT; SAFETY STANDARDS; SEALS
OSTI ID:
20494093
Research Organizations:
U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research, Division of Safety Issue Resolution, Washington, DC (United States)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
TRN: XA04N2077066272
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
89 pages
Announcement Date:

Citation Formats

Shaukat, S K, Jackson, J E, and Thatcher, D F. Regulatory analysis for Generic Issue 23: Reactor coolant pump seal failure. Draft report for comment. IAEA: N. p., 1991. Web.
Shaukat, S K, Jackson, J E, & Thatcher, D F. Regulatory analysis for Generic Issue 23: Reactor coolant pump seal failure. Draft report for comment. IAEA.
Shaukat, S K, Jackson, J E, and Thatcher, D F. 1991. "Regulatory analysis for Generic Issue 23: Reactor coolant pump seal failure. Draft report for comment." IAEA.
@misc{etde_20494093,
title = {Regulatory analysis for Generic Issue 23: Reactor coolant pump seal failure. Draft report for comment}
author = {Shaukat, S K, Jackson, J E, and Thatcher, D F}
abstractNote = {This report presents the regulatory/backfit analysis for Generic Issue 23 (GI-23), 'Reactor Coolant Pump Seal Failure'. A backfit analysis in accordance with 10 CFR 50.109 is presented in Appendix E. The proposed resolution includes quality assurance provisions for reactor coolant pump seals, instrumentation and procedures for monitoring seal performance, and provisions for seal cooling during off-normal plant conditions involving loss of all seal cooling such as station blackout. Research, technical data, and other analyses supporting the resolution of this issue are summarized in the technical findings report (NUREG/CR-4948) and cost/benefit report (NUREG/CR-5167). (author)}
place = {IAEA}
year = {1991}
month = {Apr}
}