You need JavaScript to view this

Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie

Abstract

An apparatus was developed for measuring the thermal conductivity coefficient K of irradiated or non-irradiated graphite. The measurement of K at around room temperature with an accuracy of about 6% is possible. The study specimen is placed in a vacuum between a hot and a cold source which create a temperature gradient {delta}{theta}/ {delta}x in the steady state. The amount of heat transferred, Q, is deduced from the electrical power dissipated at the hot source, after allowing for heat losses. The thermal conductivity coefficient is defined as: K = Q/S. {delta}x/{delta}{theta}, S being the cross section of the sample. Systematic studies have made it possible to determine the mean values of the thermal conductivity. (authors) [French] Un appareil de mesure du coefficient de conductibilite thermique K du graphite irradie ou non irradie a ete realise. Utilisant le principe du transfert de chaleur, il permet de mesurer K au voisinage de la temperature ambiante avec une precision de 6 pour cent environ. L'echantillon de graphite etudie est place sous vide entre une source chaude et une source froide qui creent en regime permanent un gradient de temperature {delta}{theta}/{delta}x La quantite de chaleur transferee Q est deduite de la puissance electrique dissipee  More>>
Publication Date:
Jul 01, 1962
Product Type:
Technical Report
Report Number:
CEA-R-2242
Resource Relation:
Other Information: 6 refs; PBD: 1962
Subject:
36 MATERIALS SCIENCE; GRAPHITE; HEAT FLUX; HEAT TRANSFER; IRRADIATION; TEMPERATURE GRADIENTS; THERMAL CONDUCTIVITY
OSTI ID:
20468537
Research Organizations:
Commissariat a l'Energie Atomique. Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR04R2242044247
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
24 pages
Announcement Date:

Citation Formats

Bocquet, M, and Micaud, G. Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie. France: N. p., 1962. Web.
Bocquet, M, & Micaud, G. Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie. France.
Bocquet, M, and Micaud, G. 1962. "Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie." France.
@misc{etde_20468537,
title = {Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie}
author = {Bocquet, M, and Micaud, G}
abstractNote = {An apparatus was developed for measuring the thermal conductivity coefficient K of irradiated or non-irradiated graphite. The measurement of K at around room temperature with an accuracy of about 6% is possible. The study specimen is placed in a vacuum between a hot and a cold source which create a temperature gradient {delta}{theta}/ {delta}x in the steady state. The amount of heat transferred, Q, is deduced from the electrical power dissipated at the hot source, after allowing for heat losses. The thermal conductivity coefficient is defined as: K = Q/S. {delta}x/{delta}{theta}, S being the cross section of the sample. Systematic studies have made it possible to determine the mean values of the thermal conductivity. (authors) [French] Un appareil de mesure du coefficient de conductibilite thermique K du graphite irradie ou non irradie a ete realise. Utilisant le principe du transfert de chaleur, il permet de mesurer K au voisinage de la temperature ambiante avec une precision de 6 pour cent environ. L'echantillon de graphite etudie est place sous vide entre une source chaude et une source froide qui creent en regime permanent un gradient de temperature {delta}{theta}/{delta}x La quantite de chaleur transferee Q est deduite de la puissance electrique dissipee dans la source chaude en deduisant les pertes thermiques. Le coefficient de conductibilite thermique est defini par: K = Q/S. {delta}x/{delta}{theta} S designant la section de l'echantillon. Des etudes systematiques ont permis de determiner pour differents graphites non irradies les valeurs moyennes des coefficients de conductibilite thermique. Ces etudes ont mis en evidence pour un type de graphite donne, l'influence de la densite apparente sur le coefficient de conductibilite thermique. A partir de mesures effectuees sur des echantillons de graphite irradies preleves par carottage dans les empilements des reacteurs a moderateur de graphite les variations du rapport K0/Ki en fonction de la dose et de la temperature d'irradiation ont ete deduites (K0 et Ki, coefficients de conductibilite thermique avant et apres irradiation). (auteurs)}
place = {France}
year = {1962}
month = {Jul}
}