Abstract

The principle of a differential calorimeter is briefly described. The apparatus allows a direct and continuous determination of the differential heat-capacity between a sample and a reference, in the range 20 to 600 deg. K approximately. Some examples concerning measurements at low temperatures of reversible or non reversible thermal effects are given. They show the possibilities of the apparatus and are connected with: - detection and measurements of thermal effects associated to structural transformations in elastomers at low temperatures, - measurements of Wigner energy released after neutron irradiations at 77 deg. K for: recrystallized pyro-graphites; high purity iron, aluminium. [French] On decrit brievement le principe d'un calorimetre differentiel qui permet la determination directe et continue de la difference de chaleur specifique apparente entre un echantillon et une reference, dans une gamme de temperatures s'etendant de 20 a 600 deg. K environ. On donne quelques exemples de mesure a basses temperatures d'effets thermiques reversibles ou non reversibles. Ils montrent les possibilites de l'appareillage et concernent: - la detection et la mesure d'effets thermiques associes a des transformations structurales dans des elastomeres a basse temperature, - la mesure du degagement d'energie Wigner apres des irradiations neutroniques a 77 deg. K dans: des  More>>
Publication Date:
Jul 01, 1967
Product Type:
Technical Report
Report Number:
CEA-N-818
Resource Relation:
Other Information: 5 fig; PBD: 1967
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; ALUMINIUM; CALORIMETERS; GRAPHITE; IRON; IRRADIATION; SPECIFIC HEAT; TEMPERATURE DEPENDENCE; WIGNER EFFECT
OSTI ID:
20468463
Research Organizations:
Commissariat a l'Energie Atomique, Centre d'Etudes Nucleaires de Grenoble, 38 (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR04N0818044173
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
13 pages
Announcement Date:
Jun 18, 2004

Citation Formats

Bochirol, L, and Bonjour, E. Some examples of a differential calorimeter use for low temperature thermal effects measurement; Quelques exemples d'utilisation d'un calorimetre differentiel a puissance compensee pour des mesures d'anomalies thermiques a basses temperatures. France: N. p., 1967. Web.
Bochirol, L, & Bonjour, E. Some examples of a differential calorimeter use for low temperature thermal effects measurement; Quelques exemples d'utilisation d'un calorimetre differentiel a puissance compensee pour des mesures d'anomalies thermiques a basses temperatures. France.
Bochirol, L, and Bonjour, E. 1967. "Some examples of a differential calorimeter use for low temperature thermal effects measurement; Quelques exemples d'utilisation d'un calorimetre differentiel a puissance compensee pour des mesures d'anomalies thermiques a basses temperatures." France.
@misc{etde_20468463,
title = {Some examples of a differential calorimeter use for low temperature thermal effects measurement; Quelques exemples d'utilisation d'un calorimetre differentiel a puissance compensee pour des mesures d'anomalies thermiques a basses temperatures}
author = {Bochirol, L, and Bonjour, E}
abstractNote = {The principle of a differential calorimeter is briefly described. The apparatus allows a direct and continuous determination of the differential heat-capacity between a sample and a reference, in the range 20 to 600 deg. K approximately. Some examples concerning measurements at low temperatures of reversible or non reversible thermal effects are given. They show the possibilities of the apparatus and are connected with: - detection and measurements of thermal effects associated to structural transformations in elastomers at low temperatures, - measurements of Wigner energy released after neutron irradiations at 77 deg. K for: recrystallized pyro-graphites; high purity iron, aluminium. [French] On decrit brievement le principe d'un calorimetre differentiel qui permet la determination directe et continue de la difference de chaleur specifique apparente entre un echantillon et une reference, dans une gamme de temperatures s'etendant de 20 a 600 deg. K environ. On donne quelques exemples de mesure a basses temperatures d'effets thermiques reversibles ou non reversibles. Ils montrent les possibilites de l'appareillage et concernent: - la detection et la mesure d'effets thermiques associes a des transformations structurales dans des elastomeres a basse temperature, - la mesure du degagement d'energie Wigner apres des irradiations neutroniques a 77 deg. K dans: des pyrographites recristallises; du fer de haute purete et de l'aluminium. (auteurs)}
place = {France}
year = {1967}
month = {Jul}
}