You need JavaScript to view this

A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux

Abstract

A mass spectrometer for leak detection and rapid gas analysis were constructed, having the characteristics and several structural features of a simple instrument described by Siry in Rev. Sri. Instruments. 540 (1947). Although exhibiting a good resolving power, the apparatus, which has no ion lenses and whose electrodes can be regulated during the performance, has not been sufficiently tested. Since several design defects have been discovered, it will probably be rebuilt with various improvements (ion source outside the magnetic field, modified circuits, etc.). (author)
Publication Date:
Jul 01, 1950
Product Type:
Technical Report
Report Number:
CEA-042
Resource Relation:
Other Information: PBD: 1950
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; AMPLIFIERS; ELECTRODES; ELECTRONIC CIRCUITS; FILAMENTS; GAS ANALYSIS; ION SOURCES; MASS SPECTROMETERS; OSCILLOGRAPHS; PHILIPS GAGES; POWER SUPPLIES; SPECIFICATIONS; TECHNOLOGY ASSESSMENT
OSTI ID:
20468429
Research Organizations:
Commissariat a l'Energie Atomique, Lab. du Fort de Chatillon, 92 - Fontenay-aux-Roses (France)
Country of Origin:
France
Language:
French
Other Identifying Numbers:
TRN: FR04A0042044139
Availability:
Available from INIS in electronic form
Submitting Site:
FRN
Size:
24 pages
Announcement Date:

Citation Formats

Cassignol, C, Ortel, Y, and Taieb, J. A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux. France: N. p., 1950. Web.
Cassignol, C, Ortel, Y, & Taieb, J. A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux. France.
Cassignol, C, Ortel, Y, and Taieb, J. 1950. "A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux." France.
@misc{etde_20468429,
title = {A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux}
author = {Cassignol, C, Ortel, Y, and Taieb, J}
abstractNote = {A mass spectrometer for leak detection and rapid gas analysis were constructed, having the characteristics and several structural features of a simple instrument described by Siry in Rev. Sri. Instruments. 540 (1947). Although exhibiting a good resolving power, the apparatus, which has no ion lenses and whose electrodes can be regulated during the performance, has not been sufficiently tested. Since several design defects have been discovered, it will probably be rebuilt with various improvements (ion source outside the magnetic field, modified circuits, etc.). (author)}
place = {France}
year = {1950}
month = {Jul}
}