You need JavaScript to view this

Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante

Abstract

Correlation techniques are often used to assess primary coolant flow in nuclear reactors. Observable fluctuations of some physical or chemical coolant properties are suitable for this purpose. This work describes a development carried out at the National Atomic Energy Commission of Argentina (CNEA) to apply this technique to correlate temperature fluctuations. A laboratory test was performed. Two thermocouples were installed on a hydraulic loop. A stationary flow of water circulated by the mentioned loop, where a mechanical turbine type flowmeter was installed. Transit times given by the correlation flowmeter, for different flow values measured with the mechanical flowmeter, were registered and a calibration between them was done. A very good linear behavior was obtained in all the measured range. It was necessary to increase the fluctuation level by adding water at different temperatures at the measuring system input. (author)
Authors:
Villanueva, Jose [1] 
  1. Comision Nacional de Energia Atomica, Ezeiza (Argentina). Centro Atomico Ezeiza
Publication Date:
Jul 01, 2003
Product Type:
Conference
Report Number:
INIS-AR-C-330
Resource Relation:
Conference: AATN 2002: 29. Annual meeting of the Argentine Association of Nuclear Technology, AATN 2002: 29. Reunion anual de la Asociacion Argentina de Tecnologia Nuclear (AATN), Buenos Aires (Argentina), 19-21 Nov 2002; Other Information: 2 refs., 5 figs., 1 tab; PBD: 2003
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; COOLANTS; COOLING; CORRELATION FUNCTIONS; FLOW RATE; FLUID FLOW; PRIMARY COOLANT CIRCUITS; REACTOR NOISE; REACTORS; TEMPERATURE NOISE
OSTI ID:
20405245
Country of Origin:
Argentina
Language:
Spanish
Other Identifying Numbers:
TRN: AR03C0074079890
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
11 pages
Announcement Date:
Dec 12, 2003

Citation Formats

Villanueva, Jose. Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante. Argentina: N. p., 2003. Web.
Villanueva, Jose. Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante. Argentina.
Villanueva, Jose. 2003. "Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante." Argentina.
@misc{etde_20405245,
title = {Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante}
author = {Villanueva, Jose}
abstractNote = {Correlation techniques are often used to assess primary coolant flow in nuclear reactors. Observable fluctuations of some physical or chemical coolant properties are suitable for this purpose. This work describes a development carried out at the National Atomic Energy Commission of Argentina (CNEA) to apply this technique to correlate temperature fluctuations. A laboratory test was performed. Two thermocouples were installed on a hydraulic loop. A stationary flow of water circulated by the mentioned loop, where a mechanical turbine type flowmeter was installed. Transit times given by the correlation flowmeter, for different flow values measured with the mechanical flowmeter, were registered and a calibration between them was done. A very good linear behavior was obtained in all the measured range. It was necessary to increase the fluctuation level by adding water at different temperatures at the measuring system input. (author)}
place = {Argentina}
year = {2003}
month = {Jul}
}