You need JavaScript to view this

FY 1992 report on the survey of geothermal development promotion. Geochemical survey (Survey of geothermal water) (No.36 - Hongu area); 1992 nendo chinetsu kaihatsu sokushin chosa. Chikagaku chosa (Nessui no chosa) hokokusho (No.36 Hongu chiiki)

Abstract

The test on jetting of geothermal water by the induced jetting, sampling of geothermal water and analysis/survey were carried out in the structure drilling well of N4-HG-2 in the Hongu area, Wakayama Prefecture. The induced jetting of the well was conducted by the Swabbing method up to the total pumping amount of 459.9m{sup 3} that is equal to about 24 times as much as the inner quantity of the well, but it did not result in jetting. The maximum temperature of geothermal water was 65.6 degrees C, pH was 6.6-7.5, electric conductivity was 2,800-2,900 {mu}S/cm, and Cl concentration was 500-700ppm. The geothermal water was classified into the HCO{sub 3} type that is neutral, and the spring quality and liquidity were the same as those of existing hot springs in this area. In the Hongu area, the distribution of new volcanic rocks has not known. The K-Ar age of quartz porphyry intrusive rocks was made about 13Ma, and it was considered that a possibility was low of the rocks being heat sources of geothermal activities. It was also considered that the geothermal water/hot spring water in this area, which originate in the surface water, were heated in heat transfer by magma  More>>
Publication Date:
Jul 01, 1993
Product Type:
Technical Report
Report Number:
JP-NEDO-010019298
Resource Relation:
Other Information: PBD: Jul 1993
Subject:
15 GEOTHERMAL ENERGY; GEOTHERMAL EXPLORATION; GEOTHERMAL FLUIDS; GEOTHERMAL WELLS; GEOTHERMAL SYSTEMS; SAMPLING; CHEMICAL ANALYSIS; TEMPERATURE MEASUREMENT; ELECTRIC CONDUCTIVITY; CHLORINE; PH VALUE; HOT SPRINGS; MAGMA; THERMAL CONDUCTION
OSTI ID:
20313476
Research Organizations:
New Energy and Industrial Technology Development Organization, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
TRN: JN0240548
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20313476
Submitting Site:
NEDO
Size:
64 pages
Announcement Date:
Apr 10, 2003

Citation Formats

None. FY 1992 report on the survey of geothermal development promotion. Geochemical survey (Survey of geothermal water) (No.36 - Hongu area); 1992 nendo chinetsu kaihatsu sokushin chosa. Chikagaku chosa (Nessui no chosa) hokokusho (No.36 Hongu chiiki). Japan: N. p., 1993. Web.
None. FY 1992 report on the survey of geothermal development promotion. Geochemical survey (Survey of geothermal water) (No.36 - Hongu area); 1992 nendo chinetsu kaihatsu sokushin chosa. Chikagaku chosa (Nessui no chosa) hokokusho (No.36 Hongu chiiki). Japan.
None. 1993. "FY 1992 report on the survey of geothermal development promotion. Geochemical survey (Survey of geothermal water) (No.36 - Hongu area); 1992 nendo chinetsu kaihatsu sokushin chosa. Chikagaku chosa (Nessui no chosa) hokokusho (No.36 Hongu chiiki)." Japan.
@misc{etde_20313476,
title = {FY 1992 report on the survey of geothermal development promotion. Geochemical survey (Survey of geothermal water) (No.36 - Hongu area); 1992 nendo chinetsu kaihatsu sokushin chosa. Chikagaku chosa (Nessui no chosa) hokokusho (No.36 Hongu chiiki)}
author = {None}
abstractNote = {The test on jetting of geothermal water by the induced jetting, sampling of geothermal water and analysis/survey were carried out in the structure drilling well of N4-HG-2 in the Hongu area, Wakayama Prefecture. The induced jetting of the well was conducted by the Swabbing method up to the total pumping amount of 459.9m{sup 3} that is equal to about 24 times as much as the inner quantity of the well, but it did not result in jetting. The maximum temperature of geothermal water was 65.6 degrees C, pH was 6.6-7.5, electric conductivity was 2,800-2,900 {mu}S/cm, and Cl concentration was 500-700ppm. The geothermal water was classified into the HCO{sub 3} type that is neutral, and the spring quality and liquidity were the same as those of existing hot springs in this area. In the Hongu area, the distribution of new volcanic rocks has not known. The K-Ar age of quartz porphyry intrusive rocks was made about 13Ma, and it was considered that a possibility was low of the rocks being heat sources of geothermal activities. It was also considered that the geothermal water/hot spring water in this area, which originate in the surface water, were heated in heat transfer by magma activities in the deep underground and were flowing forming a small scale of hydrothermal convection system. (NEDO)}
place = {Japan}
year = {1993}
month = {Jul}
}