Abstract
Industrial installations that are under pressure and are operating at high temperatures have a limited life due to creep and fatigue. It is, therefore, of critical importance to know the location of any possible weak spots in the installation. Welds in steam pipes, especially the heat-affected zones in these welds, are such weak spots in the long term. The material deforms and cracks may develop, with significant failure in the worst case. To avoid safety risks, unforeseen plant shutdown and, as a consequence, high costs for unavailability and repair, periodic inspections and strain measurements are recommended. KEMA's SPICA (Speckle Image Correlation Analysis) system is able to measure on-stream (during operation) deformation due to creep in critical areas, like the heat-affected zone in welds. (orig.)
Hulshof, H J.M.;
Welberg, P G.M.;
[1]
Bruijn, L.E. de
[2]
- KEMA Nederland B.V., Arnhem (Netherlands)
- E.ON Benelux Generation N.V., Rotterdam (Netherlands). Power Plant Maasvlakte
Citation Formats
Hulshof, H J.M., Welberg, P G.M., and Bruijn, L.E. de.
More plant availability by local and integral strain measurement.
Germany: N. p.,
2002.
Web.
Hulshof, H J.M., Welberg, P G.M., & Bruijn, L.E. de.
More plant availability by local and integral strain measurement.
Germany.
Hulshof, H J.M., Welberg, P G.M., and Bruijn, L.E. de.
2002.
"More plant availability by local and integral strain measurement."
Germany.
@misc{etde_20309305,
title = {More plant availability by local and integral strain measurement}
author = {Hulshof, H J.M., Welberg, P G.M., and Bruijn, L.E. de}
abstractNote = {Industrial installations that are under pressure and are operating at high temperatures have a limited life due to creep and fatigue. It is, therefore, of critical importance to know the location of any possible weak spots in the installation. Welds in steam pipes, especially the heat-affected zones in these welds, are such weak spots in the long term. The material deforms and cracks may develop, with significant failure in the worst case. To avoid safety risks, unforeseen plant shutdown and, as a consequence, high costs for unavailability and repair, periodic inspections and strain measurements are recommended. KEMA's SPICA (Speckle Image Correlation Analysis) system is able to measure on-stream (during operation) deformation due to creep in critical areas, like the heat-affected zone in welds. (orig.)}
journal = []
issue = {10}
volume = {82}
journal type = {AC}
place = {Germany}
year = {2002}
month = {Jul}
}
title = {More plant availability by local and integral strain measurement}
author = {Hulshof, H J.M., Welberg, P G.M., and Bruijn, L.E. de}
abstractNote = {Industrial installations that are under pressure and are operating at high temperatures have a limited life due to creep and fatigue. It is, therefore, of critical importance to know the location of any possible weak spots in the installation. Welds in steam pipes, especially the heat-affected zones in these welds, are such weak spots in the long term. The material deforms and cracks may develop, with significant failure in the worst case. To avoid safety risks, unforeseen plant shutdown and, as a consequence, high costs for unavailability and repair, periodic inspections and strain measurements are recommended. KEMA's SPICA (Speckle Image Correlation Analysis) system is able to measure on-stream (during operation) deformation due to creep in critical areas, like the heat-affected zone in welds. (orig.)}