You need JavaScript to view this

FY 1997 report on the data processing of the geothermal development promotion survey. Primary. No.B-5 Mt. Musadake area; 1997 nendo chinetsu kaihatsu sokushin chosa data shori hokokusho. No. B-5 Musadake chiiki (Dai 1 ji)

Abstract

As part of the geothermal development promotion survey, the comprehensive analysis was made on the survey of the existence amount of geothermal resource in the Mt. Musadake area, Shibetsu county, Hokkaido, which was conducted in FY 1997. In the surface survey, the following were carried out: survey of geology/alteration zone, age determination of rocks, alteration age determination by thermoluminescence method, geochemical survey (hot spring gas, hot spring water), gravity exploration and electromagnetic exploration. In the survey of environmental effects, survey of flora/fauna and survey of hot spring variations were made. The results of the analysis were outlined as follows. The geothermal system in this area seems to be controlled by the Mt. Musadake - Mt. Shitabanupuri fault, folding zone along the fault and Graben-state structure extending southeast of the zone. At deep underground, the existence of the deep geothermal water forming geothermal reservoirs is presumed, and the deep geothermal water seems to be helped by the thermal conduction and volcanic effluences from the magma reservoir related to a series of volcanoes, centered on Mt. Musadake that is regarded as heat source. The geothermal water has a temperature of over 250 degrees C and a high Cl concentration. (NEDO)
Authors:
"NONE"
Publication Date:
Jun 01, 1998
Product Type:
Technical Report
Report Number:
JP-NEDO-010019621
Resource Relation:
Other Information: PBD: Jun 1998
Subject:
15 GEOTHERMAL ENERGY; GEOTHERMAL EXPLORATION; GEOTHERMAL FIELDS; GEOTHERMAL RESOURCES; GEOTHERMAL SYSTEMS; GEOTHERMAL FLUIDS; GEOLOGIC SURVEYS; GEOCHEMICAL SURVEYS; ELECTROMAGNETIC SURVEYS; GRAVITY SURVEYS; HOT SPRINGS; GEOLOGIC FAULTS; MAGMA
OSTI ID:
20270994
Research Organizations:
New Energy and Industrial Technology Development Organization, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
TRN: JN0240022
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20270994
Submitting Site:
NEDO
Size:
502 pages
Announcement Date:

Citation Formats

FY 1997 report on the data processing of the geothermal development promotion survey. Primary. No.B-5 Mt. Musadake area; 1997 nendo chinetsu kaihatsu sokushin chosa data shori hokokusho. No. B-5 Musadake chiiki (Dai 1 ji). Japan: N. p., 1998. Web.
FY 1997 report on the data processing of the geothermal development promotion survey. Primary. No.B-5 Mt. Musadake area; 1997 nendo chinetsu kaihatsu sokushin chosa data shori hokokusho. No. B-5 Musadake chiiki (Dai 1 ji). Japan.
1998. "FY 1997 report on the data processing of the geothermal development promotion survey. Primary. No.B-5 Mt. Musadake area; 1997 nendo chinetsu kaihatsu sokushin chosa data shori hokokusho. No. B-5 Musadake chiiki (Dai 1 ji)." Japan.
@misc{etde_20270994,
title = {FY 1997 report on the data processing of the geothermal development promotion survey. Primary. No.B-5 Mt. Musadake area; 1997 nendo chinetsu kaihatsu sokushin chosa data shori hokokusho. No. B-5 Musadake chiiki (Dai 1 ji)}
abstractNote = {As part of the geothermal development promotion survey, the comprehensive analysis was made on the survey of the existence amount of geothermal resource in the Mt. Musadake area, Shibetsu county, Hokkaido, which was conducted in FY 1997. In the surface survey, the following were carried out: survey of geology/alteration zone, age determination of rocks, alteration age determination by thermoluminescence method, geochemical survey (hot spring gas, hot spring water), gravity exploration and electromagnetic exploration. In the survey of environmental effects, survey of flora/fauna and survey of hot spring variations were made. The results of the analysis were outlined as follows. The geothermal system in this area seems to be controlled by the Mt. Musadake - Mt. Shitabanupuri fault, folding zone along the fault and Graben-state structure extending southeast of the zone. At deep underground, the existence of the deep geothermal water forming geothermal reservoirs is presumed, and the deep geothermal water seems to be helped by the thermal conduction and volcanic effluences from the magma reservoir related to a series of volcanoes, centered on Mt. Musadake that is regarded as heat source. The geothermal water has a temperature of over 250 degrees C and a high Cl concentration. (NEDO)}
place = {Japan}
year = {1998}
month = {Jun}
}