You need JavaScript to view this

Feasibility study on waste utilization of a palm oil refinery

Abstract

As to empty fruit bunches (EFB) which are wasted at the Lahad Datu plant of Felda Vegetable Oil Products Co. in Malaysia, a project was studied for energy substitution and greenhouse effect gas reduction by fluidized bed cogeneration facilities using this as fuel. In the project, studied was the introduction of on-site cogenerator of 7,800kW in generating-end output, and that of IPP cogenerator of 16,000kW as reference. As a result of the study, the energy substitution amount in toe in 20 years was approximately 376 k tons in case of on-site power generation/fluidized bed boiler and approximately 695 k tons in case of IPP and fluidized bed boiler. The amount of greenhouse effect gas emission in toe in 20 years was approximately 5,757 k tons and 11,654 k tons, respectively. Concerning the profitability, the internal earning rate was 3.32-8.47% in case of on-site power generation/fluidized bed boiler and 9.13-14.65% in case of IPP/fluidized bed boiler. It indicated the materialization of the project. (NEDO)
Publication Date:
Mar 01, 2001
Product Type:
Technical Report
Report Number:
JP-NEDO-020005089
Resource Relation:
Other Information: PBD: Mar 2001
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; MALAYSIA; OIL PALMS; COCONUTS; WASTE PRODUCT UTILIZATION; FUEL SUBSTITUTION; COGENERATION; GREENHOUSE GASES; POLLUTION ABATEMENT; COST BENEFIT ANALYSIS; FLUIDIZED BED BOILERS
OSTI ID:
20225603
Research Organizations:
New Energy and Industrial Technology Development Organization, Tokyo (Japan)
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
TRN: JN0141218
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20225603
Submitting Site:
NEDO
Size:
[260] pages
Announcement Date:
Dec 05, 2002

Citation Formats

None. Feasibility study on waste utilization of a palm oil refinery. Japan: N. p., 2001. Web.
None. Feasibility study on waste utilization of a palm oil refinery. Japan.
None. 2001. "Feasibility study on waste utilization of a palm oil refinery." Japan.
@misc{etde_20225603,
title = {Feasibility study on waste utilization of a palm oil refinery}
author = {None}
abstractNote = {As to empty fruit bunches (EFB) which are wasted at the Lahad Datu plant of Felda Vegetable Oil Products Co. in Malaysia, a project was studied for energy substitution and greenhouse effect gas reduction by fluidized bed cogeneration facilities using this as fuel. In the project, studied was the introduction of on-site cogenerator of 7,800kW in generating-end output, and that of IPP cogenerator of 16,000kW as reference. As a result of the study, the energy substitution amount in toe in 20 years was approximately 376 k tons in case of on-site power generation/fluidized bed boiler and approximately 695 k tons in case of IPP and fluidized bed boiler. The amount of greenhouse effect gas emission in toe in 20 years was approximately 5,757 k tons and 11,654 k tons, respectively. Concerning the profitability, the internal earning rate was 3.32-8.47% in case of on-site power generation/fluidized bed boiler and 9.13-14.65% in case of IPP/fluidized bed boiler. It indicated the materialization of the project. (NEDO)}
place = {Japan}
year = {2001}
month = {Mar}
}