You need JavaScript to view this

FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka

Abstract

For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)
Publication Date:
Mar 01, 2001
Product Type:
Technical Report
Report Number:
JP-NEDO-010017510
Resource Relation:
Other Information: PBD: Mar 2001
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; FURNACES; FIELD TESTS; DATA ACQUISITION; DATA ANALYSIS; KYOTO PROTOCOL; GREENHOUSE GASES; CARBON DIOXIDE; TEMPERATURE DEPENDENCE; COMBUSTION; HEAT STORAGE; BURNERS; ENERGY CONSERVATION; NITROGEN OXIDES; QUALITY ASSURANCE; MINIATURIZATION
OSTI ID:
20208095
Research Organizations:
New Energy and Industrial Technology Development Organization, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
TRN: JN0140689
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20208095
Submitting Site:
NEDO
Size:
314 pages
Announcement Date:
Jun 11, 2002

Citation Formats

None. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka. Japan: N. p., 2001. Web.
None. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka. Japan.
None. 2001. "FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka." Japan.
@misc{etde_20208095,
title = {FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka}
author = {None}
abstractNote = {For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)}
place = {Japan}
year = {2001}
month = {Mar}
}