Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours

Abstract

The main difficulties resulting from sodium aerosols and vapours in the cover gas which have been encountered for 10 years in RAPSODIE and for 3 years in PHENIX are reviewed: condensation of sodium in annular spaces; plugging in primary gas pipes; plugging of filters and vapour traps. All those problems were easily overcome. (author)
Authors:
Delisle, J P; Reboul, M; Elie, X [1] 
  1. DRNR/STRS - Centre de Cadarache, Saint-Paul-lez-Durance (France)
Publication Date:
Jan 01, 1977
Product Type:
Conference
Report Number:
IWGFR-15
Reference Number:
EDB-01:018901
Resource Relation:
Conference: IAEA-IWGFR technical committee meeting on aerosol formation, vapour deposits and sodium vapour trapping, Cadarache (France), 13-17 Dec 1976; Other Information: 7 figs; PBD: Jan 1977; Related Information: In: Technical committee meeting on aerosol formation, vapour deposits and sodium vapour trapping. Summary report, 149 pages.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; AEROSOLS; FILTERS; PHENIX REACTOR; PLUGGING; PRIMARY COOLANT CIRCUITS; RAPSODIE REACTOR; SODIUM
OSTI ID:
20136228
Research Organizations:
International Atomic Energy Agency, International Working Group on Fast Reactors, Vienna (Austria)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
TRN: XA0100170005662
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
page(s) 25-31
Announcement Date:
Mar 02, 2001

Citation Formats

Delisle, J P, Reboul, M, and Elie, X. Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours. IAEA: N. p., 1977. Web.
Delisle, J P, Reboul, M, & Elie, X. Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours. IAEA.
Delisle, J P, Reboul, M, and Elie, X. 1977. "Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours." IAEA.
@misc{etde_20136228,
title = {Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours}
author = {Delisle, J P, Reboul, M, and Elie, X}
abstractNote = {The main difficulties resulting from sodium aerosols and vapours in the cover gas which have been encountered for 10 years in RAPSODIE and for 3 years in PHENIX are reviewed: condensation of sodium in annular spaces; plugging in primary gas pipes; plugging of filters and vapour traps. All those problems were easily overcome. (author)}
place = {IAEA}
year = {1977}
month = {Jan}
}