You need JavaScript to view this

Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais

Abstract

Active chronic osteomyelitis or complicating osteomyelitis (superimposed on diseases that changes the normal bone structure fractures, post-surgery, prosthesis) can be difficult to diagnose by anatomic radiological imaging modalities, like plain radiograph and CT. These diseases frequently cause also increased bone remodeling, leading to nonspecific uptake of Tc-99m-bone scan agents and gallium-67. New radiopharmaceuticals with greater inflammation/infection avidity and specificity are being developed, including the nonspecific polyclonal immunoglobulin (IgG) labeled with technetium-99. Tc-99m-IgG may be available as a ready to use kit, with no reported side effects, low patient absorbed radiation dose and low cost. The mechanism of IgG uptake at the inflammation site has not been fully elucidated yet. Specific (receptor linking, physico-chemical immunoglobulin properties) and nonspecific mechanisms (enhanced vascular permeability and macromolecular exudate) has been suggested. IgG scintigraphy results are affected by the isotope, labeling procedure adopted and characteristics of the inflammatory focus. Nineteen patients with suspected osteomyelitis (active chronic osteomyelitis or violated bone osteomyelitis) were studied by Tc-99m-IgG scintigraphy (directly labeled polyclonal immunoglobulin, Sandoglobuilina - Sandoz). All patients also underwent standard three-phase bone scintigraphy using methylene diphosphonate (Tc-99m-MDP), gallium-67 scintigraphy and plain radiographs. Infection was found in 8 sites. Sensitivity and specificity for Tc-99m-MDP, gallium-67 and Tc 99m-IgG  More>>
Publication Date:
Jul 01, 1996
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-3800
Reference Number:
EDB-01:018885
Resource Relation:
Other Information: TH: Tese (M.Sc.); 159 refs., 9 figs., 16 tabs; PBD: 1996
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ANTIBODIES; BONE TISSUES; GALLIUM; GALLIUM 67; MEDICINE; NUCLEAR MEDICINE; OSTEOMYELITIS; SCINTILLATIONS; SKELETON; TECHNETIUM; TECHNETIUM 99
OSTI ID:
20136212
Research Organizations:
Sao Paulo Univ., SP (Brazil). Faculdade de Medicina
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR01B0863005643
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
134 pages
Announcement Date:
Mar 02, 2001

Citation Formats

Sapienza, Marcelo Tatit. Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais. Brazil: N. p., 1996. Web.
Sapienza, Marcelo Tatit. Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais. Brazil.
Sapienza, Marcelo Tatit. 1996. "Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais." Brazil.
@misc{etde_20136212,
title = {Evaluation of the inflammatory activity in chronic osteomyelitis. Contribution of the scintigraphy with polyclonal antibodies; Avaliacao de atividade inflamatoria em osteomielite cronica. Contribuicao da cintilografia com anticorpos policlonais}
author = {Sapienza, Marcelo Tatit}
abstractNote = {Active chronic osteomyelitis or complicating osteomyelitis (superimposed on diseases that changes the normal bone structure fractures, post-surgery, prosthesis) can be difficult to diagnose by anatomic radiological imaging modalities, like plain radiograph and CT. These diseases frequently cause also increased bone remodeling, leading to nonspecific uptake of Tc-99m-bone scan agents and gallium-67. New radiopharmaceuticals with greater inflammation/infection avidity and specificity are being developed, including the nonspecific polyclonal immunoglobulin (IgG) labeled with technetium-99. Tc-99m-IgG may be available as a ready to use kit, with no reported side effects, low patient absorbed radiation dose and low cost. The mechanism of IgG uptake at the inflammation site has not been fully elucidated yet. Specific (receptor linking, physico-chemical immunoglobulin properties) and nonspecific mechanisms (enhanced vascular permeability and macromolecular exudate) has been suggested. IgG scintigraphy results are affected by the isotope, labeling procedure adopted and characteristics of the inflammatory focus. Nineteen patients with suspected osteomyelitis (active chronic osteomyelitis or violated bone osteomyelitis) were studied by Tc-99m-IgG scintigraphy (directly labeled polyclonal immunoglobulin, Sandoglobuilina - Sandoz). All patients also underwent standard three-phase bone scintigraphy using methylene diphosphonate (Tc-99m-MDP), gallium-67 scintigraphy and plain radiographs. Infection was found in 8 sites. Sensitivity and specificity for Tc-99m-MDP, gallium-67 and Tc 99m-IgG scintigraphy were, respectively, 88 and 36%, 75 and 73%,88 and 82%. All patients with false positive IgG scintigraphies had previous surgery. Other current scintigraphic procedures used in the diagnosis of osteomyelitis are also reviewed. (author)}
place = {Brazil}
year = {1996}
month = {Jul}
}