Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop

Abstract

Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.
Authors:
Tedjasari, R S; Lubis, E [1] 
  1. Radioactive-Waste Management Technology Centre, National Atomic Energy Agency of Indonesia(Indonesia)
Publication Date:
Jul 01, 1996
Product Type:
Conference
Report Number:
INIS-ID-005
Reference Number:
EDB-01:010874
Resource Relation:
Conference: Scientific Presentation of Radiation Safety and Environment, Prosiding Presentasi Ilmiah Keselamatan Radiasi dan Lingkungan, Jakarta (Indonesia), 20-21 Aug 1996; Other Information: 8 refs;3 tabs; PBD: 1996; Related Information: In: Proceeding of Radiation Safety and Environment, Prosiding Presentasi Ilmiah Keselamatan Radiasi dan Lingkungan, 351 pages.
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; CONTAMINATION; DOSE RATES; IRIDIUM ISOTOPES; MEASURING INSTRUMENTS; RADIOISOTOPES; THYROID
OSTI ID:
20127688
Research Organizations:
Standardization and Radiation Safety Research Centre, National Atomic Energy Agency of Indonesia (Indonesia)
Country of Origin:
Indonesia
Language:
Indonesian
Other Identifying Numbers:
Other: ISSN 0854-4085; TRN: ID0000077065390
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
page(s) 171-177
Announcement Date:

Citation Formats

Tedjasari, R S, and Lubis, E. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop. Indonesia: N. p., 1996. Web.
Tedjasari, R S, & Lubis, E. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop. Indonesia.
Tedjasari, R S, and Lubis, E. 1996. "Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop." Indonesia.
@misc{etde_20127688,
title = {Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop}
author = {Tedjasari, R S, and Lubis, E}
abstractNote = {Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.}
place = {Indonesia}
year = {1996}
month = {Jul}
}