Abstract
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
Gonzalez Z, M A;
[1]
Ferro F, G;
[2]
Rivera M, T;
Azorin N, J
[3]
- Departamento de Medicina Nuclear, Instituto Nacional de Pediatria (Mexico)
- Departamento de Materiales Radiactivos, Instituto nacional de Investigaciones Nucleares, Salazar, Estado de Mexico C.P. 52045 (Mexico)
- Departamento de Fisica, UAM Iztapalapa, Mexico D.F. (Mexico)
Citation Formats
Gonzalez Z, M A, Ferro F, G, Rivera M, T, and Azorin N, J.
Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias.
Mexico: N. p.,
1999.
Web.
Gonzalez Z, M A, Ferro F, G, Rivera M, T, & Azorin N, J.
Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias.
Mexico.
Gonzalez Z, M A, Ferro F, G, Rivera M, T, and Azorin N, J.
1999.
"Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias."
Mexico.
@misc{etde_20114907,
title = {Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias}
author = {Gonzalez Z, M A, Ferro F, G, Rivera M, T, and Azorin N, J}
abstractNote = {It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)}
place = {Mexico}
year = {1999}
month = {Jul}
}
title = {Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias}
author = {Gonzalez Z, M A, Ferro F, G, Rivera M, T, and Azorin N, J}
abstractNote = {It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)}
place = {Mexico}
year = {1999}
month = {Jul}
}