You need JavaScript to view this

Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade

Abstract

A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP) and Mevatron 12 (HC/FMRP/Ribeirao Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of clinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as well as, of the target clinical results. (author)
Publication Date:
Jul 01, 1993
Product Type:
Thesis/Dissertation
Report Number:
ETDE-BR-0158
Reference Number:
EDB-01:029496
Resource Relation:
Other Information: TH: Tese (Ph.D.); 111 refs., 48 figs., 14 tabs.; PBD: 1993
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; ACCELERATORS; RADIOTHERAPY; DOSIMETRY; PHYSICAL PROPERTIES; PHYSICAL RADIATION EFFECTS; CORRELATIONS; COMPARATIVE EVALUATIONS; ENERGY SPECTRA; RADIATION DOSES; QUALITY FACTOR
OSTI ID:
20108132
Research Organizations:
Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica e Quimica
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR00B0218
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20108132
Submitting Site:
BR
Size:
192 pages
Announcement Date:
Apr 16, 2001

Citation Formats

Fernandes, Rolando Fonseca. Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade. Brazil: N. p., 1993. Web.
Fernandes, Rolando Fonseca. Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade. Brazil.
Fernandes, Rolando Fonseca. 1993. "Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade." Brazil.
@misc{etde_20108132,
title = {Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade}
author = {Fernandes, Rolando Fonseca}
abstractNote = {A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP) and Mevatron 12 (HC/FMRP/Ribeirao Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of clinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as well as, of the target clinical results. (author)}
place = {Brazil}
year = {1993}
month = {Jul}
}