Abstract
On September 23, 1972 the KNK reactor was shut down due to a sodium-water reaction. Detection, localisation and possible leak development are described and discussed. Improvements on the KNK steam generator system due to this leak experience are explained. (author)
Citation Formats
Dumm, K, and Ratzel, W.
KNK steam generator leakage, evaluations and improvements.
IAEA: N. p.,
1975.
Web.
Dumm, K, & Ratzel, W.
KNK steam generator leakage, evaluations and improvements.
IAEA.
Dumm, K, and Ratzel, W.
1975.
"KNK steam generator leakage, evaluations and improvements."
IAEA.
@misc{etde_20107707,
title = {KNK steam generator leakage, evaluations and improvements}
author = {Dumm, K, and Ratzel, W}
abstractNote = {On September 23, 1972 the KNK reactor was shut down due to a sodium-water reaction. Detection, localisation and possible leak development are described and discussed. Improvements on the KNK steam generator system due to this leak experience are explained. (author)}
place = {IAEA}
year = {1975}
month = {Jul}
}
title = {KNK steam generator leakage, evaluations and improvements}
author = {Dumm, K, and Ratzel, W}
abstractNote = {On September 23, 1972 the KNK reactor was shut down due to a sodium-water reaction. Detection, localisation and possible leak development are described and discussed. Improvements on the KNK steam generator system due to this leak experience are explained. (author)}
place = {IAEA}
year = {1975}
month = {Jul}
}