Steam generators under construction for the SNR-300 power plant

Abstract

The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)
Authors:
Publication Date:
Jul 01, 1975
Product Type:
Conference
Report Number:
IWGFR-1
Reference Number:
EDB-00:099549
Resource Relation:
Conference: Study group meeting on steam generators for LMFBR's, Bensberg (Germany), 14-17 Oct 1974; Other Information: 10 figs, 3 tabs; PBD: Jul 1975; Related Information: In: Study group meeting on steam generators for LMFBR's. Summary report, 334 pages.
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; DESIGN; FABRICATION; HELICAL CONFIGURATION; PERFORMANCE TESTING; SNR REACTOR; STEAM GENERATORS
OSTI ID:
20107667
Research Organizations:
International Atomic Energy Agency, International Working Group on Fast Reactors, Vienna (Austria)
Country of Origin:
IAEA
Language:
English
Other Identifying Numbers:
TRN: XA0055687054504
Availability:
Available from INIS in electronic form
Submitting Site:
INIS
Size:
page(s) 41-49
Announcement Date:
Dec 01, 2000

Citation Formats

Essebaggers, J. Steam generators under construction for the SNR-300 power plant. IAEA: N. p., 1975. Web.
Essebaggers, J. Steam generators under construction for the SNR-300 power plant. IAEA.
Essebaggers, J. 1975. "Steam generators under construction for the SNR-300 power plant." IAEA.
@misc{etde_20107667,
title = {Steam generators under construction for the SNR-300 power plant}
author = {Essebaggers, J}
abstractNote = {The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)}
place = {IAEA}
year = {1975}
month = {Jul}
}