You need JavaScript to view this

FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho

Abstract

This paper describes the achievements in fiscal 1992 in the field tests on fuel cell power generation systems. The three locations subjected to the present analysis are all installed with 50-kW systems, whereas power generation efficiency of around 35% such as 35.3, 34.2 and 34.6% was obtained when the systems were operated at the rated output. When the load gets to below a certain load band (about 30 kW), the power generation efficiency decreases proportionately with the load. The overall efficiency including heat supply was 77.8, 70.7 and 80.3% respectively at about the rated output, showing a trend that the higher the thermal efficiency, the higher the overall efficiency. The case of generating both electric power and heat simultaneously has higher efficiency than the case of heat supply alone. The contribution rate of the fuel cell as a base load was 2.8, 4.6 and 13.6%, respectively. The system with as high value as 13.6% takes a power load following type operation mode, in which power is generated during a time band with large load during weekdays, and no power is generated at nighttime and in holidays when load is smaller, playing a role of peak responding power supply. Only one  More>>
Authors:
"NONE"
Publication Date:
Mar 01, 1993
Product Type:
Technical Report
Report Number:
JP-NEDO-010011786
Resource Relation:
Other Information: PBD: Mar 1993
Subject:
30 DIRECT ENERGY CONVERSION; FUEL CELLS; FIELD TESTS; DATA ANALYSIS; POWER RANGE 10-100 KW; ENERGY EFFICIENCY; THERMAL EFFICIENCY; COGENERATION; PEAKING POWER PLANTS
OSTI ID:
20079609
Research Organizations:
New Energy and Industrial Technology Development Organization, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
TRN: JN9940791
Availability:
Available to ETDE participating countries only(see www.etde.org); commercial reproduction prohibited; OSTI as DE20079609
Submitting Site:
NEDO
Size:
74 pages
Announcement Date:

Citation Formats

FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho. Japan: N. p., 1993. Web.
FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho. Japan.
1993. "FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho." Japan.
@misc{etde_20079609,
title = {FY1992 research report on the evaluation and analysis of data collected in fuel cell power generation field test project; 1992 nendo nenryo denchi hatsuden field test jigyo ni okeru shushu data hyoka kaiseki kenkyu hokokusho}
abstractNote = {This paper describes the achievements in fiscal 1992 in the field tests on fuel cell power generation systems. The three locations subjected to the present analysis are all installed with 50-kW systems, whereas power generation efficiency of around 35% such as 35.3, 34.2 and 34.6% was obtained when the systems were operated at the rated output. When the load gets to below a certain load band (about 30 kW), the power generation efficiency decreases proportionately with the load. The overall efficiency including heat supply was 77.8, 70.7 and 80.3% respectively at about the rated output, showing a trend that the higher the thermal efficiency, the higher the overall efficiency. The case of generating both electric power and heat simultaneously has higher efficiency than the case of heat supply alone. The contribution rate of the fuel cell as a base load was 2.8, 4.6 and 13.6%, respectively. The system with as high value as 13.6% takes a power load following type operation mode, in which power is generated during a time band with large load during weekdays, and no power is generated at nighttime and in holidays when load is smaller, playing a role of peak responding power supply. Only one trouble has occurred in an auxiliary generator in the heat recovery system. (NEDO)}
place = {Japan}
year = {1993}
month = {Mar}
}