You need JavaScript to view this

Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia

Abstract

The evaluation of absorbed dose in the case of external and internalcontamination due to radionuclides is sometimes hard, because of the difficulties in the assessment of the absorbed dose caused by electrons with energy less than 100 KeV in mucous membrane. In this work, a methodology for assessment of absorbed dose and stopping power in VYNS (co-polymer of polivinyl chloride - acetate) absorbers, for the 62.5 KeV and 84-88 KeV energy {sup 109} Cd conversion electrons, working with a 4 {pi} proportional pressurized detector, is presented. In order to assure the reproducibility of measurement conditions, one of the detector halves has been used to obtain a spectrum of a thin {sup 109} Cd source, without absorber. The other half of the detector was used in concomitance to obtain spectra with different thicknesses if absorber. The absorbed energy was obtained subtracting each spectrum with absorber from the spectrum without absorber, which were stored in a microcomputer connected to signal processing systems by ACE type interface. The VYNS weight and thickness were evaluated using common radionuclide metrology procedures. As VYNS has characteristics similar to a tissue equivalent material, the results obtained are consistent with dosimetric concepts and have a good agreement with  More>>
Publication Date:
Aug 01, 1995
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-3751
Reference Number:
EDB-00:107397
Resource Relation:
Other Information: TH: Tese (M.Sc.); 24 refs., 22 figs., 5 tabs; PBD: Aug 1995
Subject:
61 RADIATION PROTECTION AND DOSIMETRY; CADMIUM 109; ELECTRONS; ENERGY SPECTRA; EXPERIMENTAL DATA; KEV RANGE 10-100; M CODES; POLYVINYLS; PROPORTIONAL COUNTERS; RADIATION DOSES; SKIN ABSORPTION; STOPPING POWER; TISSUE-EQUIVALENT MATERIALS
OSTI ID:
20048963
Research Organizations:
Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
TRN: BR0039975012935
Availability:
Available from INIS in electronic form
Submitting Site:
BRN
Size:
114 pages
Announcement Date:
Dec 18, 2000

Citation Formats

Almeida, Ivan Pedro Salati de. Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia. Brazil: N. p., 1995. Web.
Almeida, Ivan Pedro Salati de. Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia. Brazil.
Almeida, Ivan Pedro Salati de. 1995. "Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia." Brazil.
@misc{etde_20048963,
title = {Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia}
author = {Almeida, Ivan Pedro Salati de}
abstractNote = {The evaluation of absorbed dose in the case of external and internalcontamination due to radionuclides is sometimes hard, because of the difficulties in the assessment of the absorbed dose caused by electrons with energy less than 100 KeV in mucous membrane. In this work, a methodology for assessment of absorbed dose and stopping power in VYNS (co-polymer of polivinyl chloride - acetate) absorbers, for the 62.5 KeV and 84-88 KeV energy {sup 109} Cd conversion electrons, working with a 4 {pi} proportional pressurized detector, is presented. In order to assure the reproducibility of measurement conditions, one of the detector halves has been used to obtain a spectrum of a thin {sup 109} Cd source, without absorber. The other half of the detector was used in concomitance to obtain spectra with different thicknesses if absorber. The absorbed energy was obtained subtracting each spectrum with absorber from the spectrum without absorber, which were stored in a microcomputer connected to signal processing systems by ACE type interface. The VYNS weight and thickness were evaluated using common radionuclide metrology procedures. As VYNS has characteristics similar to a tissue equivalent material, the results obtained are consistent with dosimetric concepts and have a good agreement with those of the literature. (author)}
place = {Brazil}
year = {1995}
month = {Aug}
}