You need JavaScript to view this

Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten

Abstract

Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with  More>>
Authors:
Biederer, J; Hutzelmann, A; Heller, M; [1]  Rama, B [2] 
  1. Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie
  2. Paracelsus Klinik, Osnabrueck (Germany). Klinik fuer Neurochirurgie
Publication Date:
Aug 01, 1999
Product Type:
Journal Article
Reference Number:
EDB-00:004846
Resource Relation:
Journal Name: RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der Neuen Bildgebenden Verfahren; Journal Volume: 171; Journal Issue: 2; Other Information: PBD: Aug 1999
Subject:
55 BIOLOGY AND MEDICINE, BASIC STUDIES; VERTEBRAE; BIOMEDICAL RADIOGRAPHY; TITANIUM; IMPLANTS; SURGERY; COMPRESSION
OSTI ID:
20003649
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: ISSN 0936-6652; RFGVEF; TRN: DE99FC583
Submitting Site:
DEN
Size:
page(s) 95-99
Announcement Date:
Mar 09, 2000

Citation Formats

Biederer, J, Hutzelmann, A, Heller, M, and Rama, B. Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten. Germany: N. p., 1999. Web.
Biederer, J, Hutzelmann, A, Heller, M, & Rama, B. Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten. Germany.
Biederer, J, Hutzelmann, A, Heller, M, and Rama, B. 1999. "Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten." Germany.
@misc{etde_20003649,
title = {Follow-up radiographs of the cervical spine after anterior fusion with titanium intervertebral disc; Roentgen-Verlaufsuntersuchung der Halswirbelsaeule nach anteriorer Fusion mit Titaninterponaten}
author = {Biederer, J, Hutzelmann, A, Heller, M, and Rama, B}
abstractNote = {Purpose: We examined the postoperative changes of the cervical spine after treatment of cervical nerve root compression with anterior cervical discectomy and fusion with a new titanium intervertebral disc. Patients and Methods: 37 patients were examined prior to, as well as 4 days, 6 weeks, and 7 months after surgery. Lateral view X-rays and functional imaging were used to evaluate posture and mobility of the cervical spine, the position of the implants, and the reactions of adjacent bone structures. Results: Implantation of the titanium disc led to post-operative distraction of the intervertebral space and slight lordosis. Within the first 6 months a slight loss of distraction and re-kyphosis due to impression of the implants into the vertebral end-plates were found in all patients. We noted partial infractions into the vertebral end-plates in 10/42 segments and slight mobility of the implants in 14/42 segments. Both groups of patients showed reactive spondylosis and local symptoms due to loosening of the implants. The pain subsided after onset of bone bridging and stable fixation of the loosened discs. Conclusions: The titanium intervertebral disc provides initial distraction of the fusioned segments with partial recurrence of kyphosis during the subsequent course. Loosening of the implants with local symptoms can be evaluated with follow-up X-rays and functional imaging. (orig.) [German] Ziel: An Patienten mit zervikalen Kompressionssyndromen wurden Stellung und Funktion der Halswirbelsaeule nach Diskektomie und Fusion mit einem neuartigen Titaninterponat untersucht. Patienten und Methoden: Bei 37 Patienten (42 Segmente) wurden praeoperativ sowie 4 Tage, 6 Wochen und 7 Monate postoperativ mit seitlichen Uebersichts- und Funktionsaufnahmen Stellung und Mobilitaet der HWS beurteilt. Erfasst wurden Lageveraenderungen des Titaninterponates und die Reaktion der angrenzenden Wirbelkoerperabschlussplatten. Ergebnisse: Das Titaninterponat bewirkte postoperativ eine messbare Aufrichtung des Zwischenwirbelraumes mit leichter Lordosierung. Innerhalb der ersten 6 Monate kam es durch Einarbeiten des Interponates in die Wirbelkoerperabschlussplatten bei allen Patienten erneut zu einer leichten Hoehenminderung mit Re-Kyphosierung im operierten Segment. In 10/42 Segmenten brach das Implantat partiell ein, in 14/42 wurde eine voruebergehende Restmobilitaet nachgewiesen. Infolge der Implantatlockerung traten bei beiden Patientengruppen lokale Beschwerden auf, die mit beginnender knoecherner Ueberbrueckung und funktionsstabiler Fixierung des Implantates durch eine reaktive Spondylose zurueckgingen. Schlussfolgerungen: Mit dem Titaninterponat wird eine initiale segmentale Aufrichtung erreicht, die sich im weiteren Verlauf teilweise zurueckbildet. Mit Uebersichts- und Funktionsaufnahmen laesst sich haeufig eine Implantatlockerung als Ursache sekundaerer Beschwerden erfassen. (orig.)}
journal = []
issue = {2}
volume = {171}
journal type = {AC}
place = {Germany}
year = {1999}
month = {Aug}
}