Abstract
This research project is aimed to analyse problems of soil-structure-equipment interaction under seismic excitation in case of Kozloduy NPP. Reevaluation and upgrading of Kozloduy NPP has started after 1977 Vrancea earthquake. New Safe Shutdown Earthquake (SSE) level was defined, upgrading most of structural equipment was performed, seismic instrumentation was installed. New investigations were initiated after 1990 IAEA mission visited the site. A comprehensive site confirmation project was started with a subsequent structural and equipment reevaluation and upgrading. This work deals with Units 5 and 6 of WWER-1000 type only.
Kostov, M
[1]
- Bulgarian Academy of Sciences, Central Laboratory for Seismic Mechanics and Earthquake Engineering, Sofia (Bulgaria)
Citation Formats
Kostov, M.
Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP.
IAEA: N. p.,
1995.
Web.
Kostov, M.
Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP.
IAEA.
Kostov, M.
1995.
"Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP."
IAEA.
@misc{etde_20002961,
title = {Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP}
author = {Kostov, M}
abstractNote = {This research project is aimed to analyse problems of soil-structure-equipment interaction under seismic excitation in case of Kozloduy NPP. Reevaluation and upgrading of Kozloduy NPP has started after 1977 Vrancea earthquake. New Safe Shutdown Earthquake (SSE) level was defined, upgrading most of structural equipment was performed, seismic instrumentation was installed. New investigations were initiated after 1990 IAEA mission visited the site. A comprehensive site confirmation project was started with a subsequent structural and equipment reevaluation and upgrading. This work deals with Units 5 and 6 of WWER-1000 type only.}
place = {IAEA}
year = {1995}
month = {Jul}
}
title = {Seismic soil-structure-equipment interaction analysis of unit 5/6, Kozloduy NPP}
author = {Kostov, M}
abstractNote = {This research project is aimed to analyse problems of soil-structure-equipment interaction under seismic excitation in case of Kozloduy NPP. Reevaluation and upgrading of Kozloduy NPP has started after 1977 Vrancea earthquake. New Safe Shutdown Earthquake (SSE) level was defined, upgrading most of structural equipment was performed, seismic instrumentation was installed. New investigations were initiated after 1990 IAEA mission visited the site. A comprehensive site confirmation project was started with a subsequent structural and equipment reevaluation and upgrading. This work deals with Units 5 and 6 of WWER-1000 type only.}
place = {IAEA}
year = {1995}
month = {Jul}
}