Abstract

The optimization using of {sup 3}H-DHT RIA Kit is studied. By narrowing the range of DHT standards, adjusting the proportion of labeled antigen and antibody, and using small volume liquid scintillation counting, the improved method makes the RIA sensitivity three times raised, a half of sample decreased and more than 80% of scintillation waste liquid reduced. The result shows that the fitting of improved calibration curve is of accuracy and precision. The correlativity of unimproved and improved method is quite well (r = 0.9211, P<0.01).
Authors:
Yanxing, Guan; Zhenqiu, Hu; Waigou, Li; Jinshui, Zhou; Zhantian, Tan [1] 
  1. Jiangxi Medical College, Nanchang (China). Dept. of Nuclear Medicine
Publication Date:
Feb 01, 1995
Product Type:
Journal Article
Reference Number:
SCA: 550601; PA: AIX-27:014237; EDB-96:040451; SN: 96001545600
Resource Relation:
Journal Name: Tongweisu (Journal of Isotopes); Journal Volume: 8; Journal Issue: 1; Other Information: PBD: Feb 1995
Subject:
55 BIOLOGY AND MEDICINE, BASIC STUDIES; LABELLED COMPOUNDS; TESTOSTERONE; RADIOIMMUNOASSAY; PROSTATE; SENSITIVITY; TRITIUM; UROGENITAL SYSTEM DISEASES
OSTI ID:
185331
Country of Origin:
China
Language:
Chinese
Other Identifying Numbers:
Journal ID: TONGEM; ISSN 1000-7512; TRN: CN9600047014237
Submitting Site:
INIS
Size:
pp. 38-41
Announcement Date:
Feb 28, 1996

Citation Formats

Yanxing, Guan, Zhenqiu, Hu, Waigou, Li, Jinshui, Zhou, and Zhantian, Tan. Some improving suggestions on using {sup 3}H-DHT radioimmunoassay kit. China: N. p., 1995. Web.
Yanxing, Guan, Zhenqiu, Hu, Waigou, Li, Jinshui, Zhou, &amp; Zhantian, Tan. Some improving suggestions on using {sup 3}H-DHT radioimmunoassay kit. China.
Yanxing, Guan, Zhenqiu, Hu, Waigou, Li, Jinshui, Zhou, and Zhantian, Tan. 1995. "Some improving suggestions on using {sup 3}H-DHT radioimmunoassay kit." China.
@misc{etde_185331,
title = {Some improving suggestions on using {sup 3}H-DHT radioimmunoassay kit}
author = {Yanxing, Guan, Zhenqiu, Hu, Waigou, Li, Jinshui, Zhou, and Zhantian, Tan}
abstractNote = {The optimization using of {sup 3}H-DHT RIA Kit is studied. By narrowing the range of DHT standards, adjusting the proportion of labeled antigen and antibody, and using small volume liquid scintillation counting, the improved method makes the RIA sensitivity three times raised, a half of sample decreased and more than 80% of scintillation waste liquid reduced. The result shows that the fitting of improved calibration curve is of accuracy and precision. The correlativity of unimproved and improved method is quite well (r = 0.9211, P<0.01).}
journal = []
issue = {1}
volume = {8}
journal type = {AC}
place = {China}
year = {1995}
month = {Feb}
}