R502/R22 - replacement refrigerant R507 in commercial refrigeration; R502/R22 - Ersatzkaeltemittel R507 in der Gewerbekuehlung. Anwendungstechnik - Kaeltemittel

Abstract

The suitability of the azeotropic refrigerant R 507 as a replacement refrigerant for R 502 is documented in this article. The differences between the azeotropic refrigerants R 502 and R 507 are made clear by phase equilibrium calculations. While the azeotrope point of the refrigerant R 502 is 19 C, in a great concentration range at low temperatures for the mixture R 125/ R 143a there is a boiling point lens with low pressure differences. The azeotrope point of the mixture is at atmospheric pressure and with a concentration of 15% R 125 and 47% R 143a. From the comparison of compressor output measurements, It is clear that this is comparable with R 502. Compared with the refrigerant R 404A, higher refrigeration output figures were determined for the refrigerant R 507 in the measurements. Comparative measurements on cooling through evaporators largely showed the same air temperatures for equipment with comparable energy consumptions for the refrigerants R 502 and R 507. (orig.) [Deutsch] Die Eignung des azeotropen Kaeltemittels R507 als R502 - Ersatzkaeltemittel wurde in diesem Beitrag dokumentiert. Anhand von Phasengleichgewichtsrechnungen wurden die Unterschiede der azeotropen Kaeltemittel R502 und R507 verdeutlicht. Waehrend der azeotrope Punkt des Kaeltemittels R502 bei 19 C  More>>
Authors:
Koenig, H [1] 
  1. Solvay Fluor und Derivate GmbH, Hannover (Germany)
Publication Date:
Dec 31, 1995
Product Type:
Miscellaneous
Report Number:
CONF-9411195-
Reference Number:
SCA: 320303; PA: DE-96:0G0716; EDB-96:015903; SN: 96001523913
Resource Relation:
Conference: German refrigeration and air conditioning meeting and general meeting of Deutscher Kaelte- und Klimatechnischer Verein e.V. (DKV), Deutsche Kaelte-Klimatagung und Ordentliche Hauptversammlung des Deutschen Kaelte- und Klimatechnischen Verein e.V. (DKV), Bonn (Germany), 16-18 Nov 1994; Other Information: PBD: [1995]; Related Information: Is Part Of DKV congress report. 21st year (1994). Vol. 2/2. Working section 2.2; PB: 287 p.; DKV-Tagungsbericht. 21. Jahrgang (1994). Bd. 2/2. Arbeitsabteilung 2.2
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; REFRIGERATING MACHINERY; OPERATION; REFRIGERANTS; RETROFITTING; THERMODYNAMIC PROPERTIES; PHASE DIAGRAMS; HEAT TRANSFER; COMPRESSORS
OSTI ID:
167601
Research Organizations:
Deutscher Kaelte- und Klimatechnischer Verein e.V., Stuttgart (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ISBN 3-922429-71-8; TRN: DE96G0716
Availability:
Available from TIB Hannover: RN 3592(21,2.2)+a
Submitting Site:
DE
Size:
pp. 193-205
Announcement Date:
Jan 17, 2004

Citation Formats

Koenig, H. R502/R22 - replacement refrigerant R507 in commercial refrigeration; R502/R22 - Ersatzkaeltemittel R507 in der Gewerbekuehlung. Anwendungstechnik - Kaeltemittel. Germany: N. p., 1995. Web.
Koenig, H. R502/R22 - replacement refrigerant R507 in commercial refrigeration; R502/R22 - Ersatzkaeltemittel R507 in der Gewerbekuehlung. Anwendungstechnik - Kaeltemittel. Germany.
Koenig, H. 1995. "R502/R22 - replacement refrigerant R507 in commercial refrigeration; R502/R22 - Ersatzkaeltemittel R507 in der Gewerbekuehlung. Anwendungstechnik - Kaeltemittel." Germany.
@misc{etde_167601,
title = {R502/R22 - replacement refrigerant R507 in commercial refrigeration; R502/R22 - Ersatzkaeltemittel R507 in der Gewerbekuehlung. Anwendungstechnik - Kaeltemittel}
author = {Koenig, H}
abstractNote = {The suitability of the azeotropic refrigerant R 507 as a replacement refrigerant for R 502 is documented in this article. The differences between the azeotropic refrigerants R 502 and R 507 are made clear by phase equilibrium calculations. While the azeotrope point of the refrigerant R 502 is 19 C, in a great concentration range at low temperatures for the mixture R 125/ R 143a there is a boiling point lens with low pressure differences. The azeotrope point of the mixture is at atmospheric pressure and with a concentration of 15% R 125 and 47% R 143a. From the comparison of compressor output measurements, It is clear that this is comparable with R 502. Compared with the refrigerant R 404A, higher refrigeration output figures were determined for the refrigerant R 507 in the measurements. Comparative measurements on cooling through evaporators largely showed the same air temperatures for equipment with comparable energy consumptions for the refrigerants R 502 and R 507. (orig.) [Deutsch] Die Eignung des azeotropen Kaeltemittels R507 als R502 - Ersatzkaeltemittel wurde in diesem Beitrag dokumentiert. Anhand von Phasengleichgewichtsrechnungen wurden die Unterschiede der azeotropen Kaeltemittel R502 und R507 verdeutlicht. Waehrend der azeotrope Punkt des Kaeltemittels R502 bei 19 C liegt, existiert fuer das Gemisch R125/R143a in einem grossen Konzentrationsbereich bei tiefen Temperaturen eine Siedelinse mit geringen Druckunterschieden. Der azeotrope Punkt des Gemisches liegt bei Atmosphaerendruck und der Konzentration 53% R125 und 47% R143a. Aus der Gegenueberstellung von Verdichterleistungsmessungen wurde deutlich, dass eine Vergleichbarkeit mit R502 gegeben ist. In Messungen wurden, verglichen mit dem Kaeltemittel R404A hoehere Kaelteleistungszahlen mit dem Kaeltemittel R507 ermittelt. Vergleichmessungen an Kuehlmoebelverdampfern ergaben fuer die Kaeltemittel R502 und R507 im wesentlichen gleiche Lufttemperaturen im Kuehlmoebel bei vergleichbaren Energieverbraeuchen. (orig.)}
place = {Germany}
year = {1995}
month = {Dec}
}