The technique for determination of surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements

Abstract

The NDT method for determining the surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements, the process of standard specimen preparation and the graduation curve are described. The measurement results of U{sub 3}Si{sub 2}-Al plate-type fuel elements show that the alpha counting method to measure the surface contamination by uranium on fuel plate is more reliable. The UB-1 type surface contamination meter, which was recently developed, has many advantages such as high sensitivity to determine the uranium pollution, short time in measuring, convenience for operation, and the minimum detectable amount of uranium is 5 x 10{sup -10} g/cm{sup 2}. The measuring device is controlled by a microcomputer. Besides data acquisition and processing, it has functions of statistics, output data on terminal or to printer and alarm. The procedures of measurement are fully automatic. All of these will meet the measuring needs in batch process.
Authors:
Shulan, Li; Fengqi, He; [1]  Qingheng, Wang; Jingquan, Han [2] 
  1. China Nuclear Power Inst., Chengdu (China)
  2. China Inst. for Radiation Protection, Taiyuan (China)
Publication Date:
Apr 01, 1993
Product Type:
Technical Report
Report Number:
CNIC-00725; SINRE-0038.
Reference Number:
SCA: 420500; PA: AIX-25:040329; EDB-94:090178; ERA-19:022227; NTS-94:023653; SN: 94001031565
Resource Relation:
Other Information: PBD: Apr 1993
Subject:
42 ENGINEERING; FUEL ELEMENTS; SURFACE CONTAMINATION; URANIUM COMPOUNDS; ALPHA DETECTION; NONDESTRUCTIVE TESTING; ALUMINIUM; AUTOMATION; MICROCOMPUTERS; SENSITIVITY; SILICIDES; 420500; MATERIALS TESTING
OSTI ID:
10157314
Research Organizations:
China Nuclear Information Centre, Beijing, BJ (China)
Country of Origin:
China
Language:
Chinese
Other Identifying Numbers:
Other: ON: DE94626278; ISBN 7-5022-0903-4; TRN: CN9400815040329
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
8 p.
Announcement Date:
Jul 06, 2005

Citation Formats

Shulan, Li, Fengqi, He, Qingheng, Wang, and Jingquan, Han. The technique for determination of surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements. China: N. p., 1993. Web.
Shulan, Li, Fengqi, He, Qingheng, Wang, & Jingquan, Han. The technique for determination of surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements. China.
Shulan, Li, Fengqi, He, Qingheng, Wang, and Jingquan, Han. 1993. "The technique for determination of surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements." China.
@misc{etde_10157314,
title = {The technique for determination of surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements}
author = {Shulan, Li, Fengqi, He, Qingheng, Wang, and Jingquan, Han}
abstractNote = {The NDT method for determining the surface contamination by uranium on U{sub 3}Si{sub 2}-Al plate-type fuel elements, the process of standard specimen preparation and the graduation curve are described. The measurement results of U{sub 3}Si{sub 2}-Al plate-type fuel elements show that the alpha counting method to measure the surface contamination by uranium on fuel plate is more reliable. The UB-1 type surface contamination meter, which was recently developed, has many advantages such as high sensitivity to determine the uranium pollution, short time in measuring, convenience for operation, and the minimum detectable amount of uranium is 5 x 10{sup -10} g/cm{sup 2}. The measuring device is controlled by a microcomputer. Besides data acquisition and processing, it has functions of statistics, output data on terminal or to printer and alarm. The procedures of measurement are fully automatic. All of these will meet the measuring needs in batch process.}
place = {China}
year = {1993}
month = {Apr}
}