Abstract
A system for detection of optical radiation and on-line diagnostics of special sized of beam and particle density distribution is described. The system is based on two hodoscope photomultipliers, scintillators, fiber optics line of transfer and electronic blocks. The system is intended for beam monitoring at the c-{tau}- factory and synchrophasotron accelerating complex at energies 20 MeV - 10 GeV and intensity range of 10{sup 3}-10{sup 8} part./cm{sup 2}. The optical parts, detector construction, hardware and software are briefly described. (author.). 2 refs.; 3 figs.; 1 tab.
Citation Formats
Kondrashov, V D, Kuz`michev, A R, Larin, A A, Lustov, N M, Mal`tsev, A A, Mal`tsev, M A, and Fedunov, A G.
Scintillation hodoscope for accelerating beams. Proposal; Stsintillyatsionnyj godoskop dlya uskoryaemykh puchkov; Predlozhenie.
JINR: N. p.,
1993.
Web.
Kondrashov, V D, Kuz`michev, A R, Larin, A A, Lustov, N M, Mal`tsev, A A, Mal`tsev, M A, & Fedunov, A G.
Scintillation hodoscope for accelerating beams. Proposal; Stsintillyatsionnyj godoskop dlya uskoryaemykh puchkov; Predlozhenie.
JINR.
Kondrashov, V D, Kuz`michev, A R, Larin, A A, Lustov, N M, Mal`tsev, A A, Mal`tsev, M A, and Fedunov, A G.
1993.
"Scintillation hodoscope for accelerating beams. Proposal; Stsintillyatsionnyj godoskop dlya uskoryaemykh puchkov; Predlozhenie."
JINR.
@misc{etde_10157309,
title = {Scintillation hodoscope for accelerating beams. Proposal; Stsintillyatsionnyj godoskop dlya uskoryaemykh puchkov; Predlozhenie}
author = {Kondrashov, V D, Kuz`michev, A R, Larin, A A, Lustov, N M, Mal`tsev, A A, Mal`tsev, M A, and Fedunov, A G}
abstractNote = {A system for detection of optical radiation and on-line diagnostics of special sized of beam and particle density distribution is described. The system is based on two hodoscope photomultipliers, scintillators, fiber optics line of transfer and electronic blocks. The system is intended for beam monitoring at the c-{tau}- factory and synchrophasotron accelerating complex at energies 20 MeV - 10 GeV and intensity range of 10{sup 3}-10{sup 8} part./cm{sup 2}. The optical parts, detector construction, hardware and software are briefly described. (author.). 2 refs.; 3 figs.; 1 tab.}
place = {JINR}
year = {1993}
month = {Dec}
}
title = {Scintillation hodoscope for accelerating beams. Proposal; Stsintillyatsionnyj godoskop dlya uskoryaemykh puchkov; Predlozhenie}
author = {Kondrashov, V D, Kuz`michev, A R, Larin, A A, Lustov, N M, Mal`tsev, A A, Mal`tsev, M A, and Fedunov, A G}
abstractNote = {A system for detection of optical radiation and on-line diagnostics of special sized of beam and particle density distribution is described. The system is based on two hodoscope photomultipliers, scintillators, fiber optics line of transfer and electronic blocks. The system is intended for beam monitoring at the c-{tau}- factory and synchrophasotron accelerating complex at energies 20 MeV - 10 GeV and intensity range of 10{sup 3}-10{sup 8} part./cm{sup 2}. The optical parts, detector construction, hardware and software are briefly described. (author.). 2 refs.; 3 figs.; 1 tab.}
place = {JINR}
year = {1993}
month = {Dec}
}