You need JavaScript to view this

Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection; Cintilografia miocardica com galio-67 na deteccao de rejeicao cardiaca aguda

Abstract

In order to evaluate the myocardial scintigraphy with Gallium-67 potentiality in the detection of acute rejection phenomenon, 105 studies were performed in 20 patients after they had a heart transplantation. The scintigraphic images were obtained by a conventional camera-computer system. These images were acquired 48 hours after all the patients were given an intravenous injection of 111 MBq of Gallium-67 Citrate. The biopsies were done according to the Mason technique and the histological analysis followed the Billingham standards. (author).
Authors:
Publication Date:
Dec 31, 1990
Product Type:
Thesis/Dissertation
Report Number:
INIS-BR-3312
Reference Number:
SCA: 550601; PA: AIX-25:040018; EDB-94:091185; ERA-19:022659; NTS-94:023618; SN: 94001031407
Resource Relation:
Other Information: TH: Tese (Ph.D.).; PBD: 1990
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; MYOCARDIUM; GALLIUM 67; SCINTISCANNING; BIOPSY; CITRATES; DIAGNOSIS; HISTOLOGICAL TECHNIQUES; IMAGES; INTRAVENOUS INJECTION; PATIENTS; TRANSPLANTS; 550601; UNSEALED RADIONUCLIDES IN DIAGNOSTICS
OSTI ID:
10157140
Research Organizations:
Sao Paulo Univ., SP (Brazil). Faculdade de Medicina
Country of Origin:
Brazil
Language:
Portuguese
Other Identifying Numbers:
Other: ON: DE94626135; TRN: BR9432017040018
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
86 p.
Announcement Date:
Jul 06, 2005

Citation Formats

Meneguetti, J C. Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection; Cintilografia miocardica com galio-67 na deteccao de rejeicao cardiaca aguda. Brazil: N. p., 1990. Web.
Meneguetti, J C. Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection; Cintilografia miocardica com galio-67 na deteccao de rejeicao cardiaca aguda. Brazil.
Meneguetti, J C. 1990. "Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection; Cintilografia miocardica com galio-67 na deteccao de rejeicao cardiaca aguda." Brazil.
@misc{etde_10157140,
title = {Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection; Cintilografia miocardica com galio-67 na deteccao de rejeicao cardiaca aguda}
author = {Meneguetti, J C}
abstractNote = {In order to evaluate the myocardial scintigraphy with Gallium-67 potentiality in the detection of acute rejection phenomenon, 105 studies were performed in 20 patients after they had a heart transplantation. The scintigraphic images were obtained by a conventional camera-computer system. These images were acquired 48 hours after all the patients were given an intravenous injection of 111 MBq of Gallium-67 Citrate. The biopsies were done according to the Mason technique and the histological analysis followed the Billingham standards. (author).}
place = {Brazil}
year = {1990}
month = {Dec}
}