You need JavaScript to view this

Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp

Abstract

An integral communication and spectral analysis system (SICADE) was developed and implemented to satisfy the need to optimize and automate the measurement system used in Atucha I nuclear power plant for the activity in the primary loop`s water extracted by the TV system. The importance of these measurements is based on the fact that from the spectrometric analysis of the samples extracted, the Iodines-GN and Iodines-Iodines relations, which allow to detect the presence of deficient fuel elements, are calculated. The system developed is based on two modules integrated in a unique set commanded by the operators through the screen dialogue. (Author). [Espanol] Dada la necesidad de optimizar y automatizar el sistema de medicion utilizado en la Central Nuclear Atucha I para la actividad en el agua del circuito primario extraida a traves del sistema TV se desarrollo e implemento un sistema integral de Comunicacion y Analisis de espectros (SICADE). La importancia de estas mediciones radica en el hecho que del analisis espectrometrico de las muestras extraidas se calculan las relaciones entre Iodos-GN e Iodos-Iodos que permiten detectar la presencia de elementos combustibles fallados. El sistema desarrollado esta basado en dos modulos integrados en un unico conjunto comandado por el operador  More>>
Publication Date:
Dec 31, 1990
Product Type:
Conference
Report Number:
INIS-mf-13296; CONF-9010363-
Reference Number:
SCA: 440102; 220200; PA: AIX-23:054468; SN: 92000775032
Resource Relation:
Conference: 18. annual meeting of the Argentine Association of Nuclear Technology (AANT),18. Reunion anual de la Asociacion Argentina de Tecnologia Nuclear,Buenos Aires (Argentina),22-26 Oct 1990; Other Information: DN: Pre-conference paper.; PBD: 1990
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 22 GENERAL STUDIES OF NUCLEAR REACTORS; GAMMA SPECTROMETERS; DATA TRANSMISSION SYSTEMS; GAMMA FUEL SCANNING; FAILED ELEMENT DETECTION; GAMMA DETECTION; GERMANIUM; PRIMARY COOLANT CIRCUITS; 440102; 220200; RADIATION DOSEMETERS; COMPONENTS AND ACCESSORIES
OSTI ID:
10156672
Research Organizations:
Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Seguridad Radiologica y Nuclear
Country of Origin:
Argentina
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE92636631; TRN: AR9200126054468
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
8 p.
Announcement Date:
Jul 06, 2005

Citation Formats

Fernandez, J, Castano, P, Bonino, A D, and Righetti, M A. Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp. Argentina: N. p., 1990. Web.
Fernandez, J, Castano, P, Bonino, A D, & Righetti, M A. Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp. Argentina.
Fernandez, J, Castano, P, Bonino, A D, and Righetti, M A. 1990. "Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp." Argentina.
@misc{etde_10156672,
title = {Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp}
author = {Fernandez, J, Castano, P, Bonino, A D, and Righetti, M A}
abstractNote = {An integral communication and spectral analysis system (SICADE) was developed and implemented to satisfy the need to optimize and automate the measurement system used in Atucha I nuclear power plant for the activity in the primary loop`s water extracted by the TV system. The importance of these measurements is based on the fact that from the spectrometric analysis of the samples extracted, the Iodines-GN and Iodines-Iodines relations, which allow to detect the presence of deficient fuel elements, are calculated. The system developed is based on two modules integrated in a unique set commanded by the operators through the screen dialogue. (Author). [Espanol] Dada la necesidad de optimizar y automatizar el sistema de medicion utilizado en la Central Nuclear Atucha I para la actividad en el agua del circuito primario extraida a traves del sistema TV se desarrollo e implemento un sistema integral de Comunicacion y Analisis de espectros (SICADE). La importancia de estas mediciones radica en el hecho que del analisis espectrometrico de las muestras extraidas se calculan las relaciones entre Iodos-GN e Iodos-Iodos que permiten detectar la presencia de elementos combustibles fallados. El sistema desarrollado esta basado en dos modulos integrados en un unico conjunto comandado por el operador a traves del dialogo por pantalla. (Autor).}
place = {Argentina}
year = {1990}
month = {Dec}
}