Abstract
An amorphous surge blocker for a high voltage acceleration power supply for the neutral beam injectors has been developed. Since the saturation magnetic flux density of the amorphous core is higher than that of the ferrite core, the surge blocker made of amorphous cores can be reduced in size appreciably compared to the conventional ferrite surge blocker. A 350 kV, 0.05 volt-second amorphous surge blocker was designed, fabricated and tested. The amorphous core was made by winding an amorphous tape with a film for the layer insulation and was heat-treated to recover the magnetic characteristics. The core is molded by epoxy resin and installed in a FRP insulator tube filled with SF{sub 6} gas for the insulation. The volt-second measured was higher than the designed value and the electrical breakdown along the cores and between layers was not observed. This test result shows that the amorphous surge blocker is applicable for a dc acceleration power supply for high energy neutral beam injectors. (author).
Mizuno, Makoto;
Ohara, Yoshihiro;
Watanabe, Kazuhiro;
[1]
Ozaki, Akira
- Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment
Citation Formats
Mizuno, Makoto, Ohara, Yoshihiro, Watanabe, Kazuhiro, and Ozaki, Akira.
Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors.
Japan: N. p.,
1993.
Web.
Mizuno, Makoto, Ohara, Yoshihiro, Watanabe, Kazuhiro, & Ozaki, Akira.
Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors.
Japan.
Mizuno, Makoto, Ohara, Yoshihiro, Watanabe, Kazuhiro, and Ozaki, Akira.
1993.
"Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors."
Japan.
@misc{etde_10156091,
title = {Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors}
author = {Mizuno, Makoto, Ohara, Yoshihiro, Watanabe, Kazuhiro, and Ozaki, Akira}
abstractNote = {An amorphous surge blocker for a high voltage acceleration power supply for the neutral beam injectors has been developed. Since the saturation magnetic flux density of the amorphous core is higher than that of the ferrite core, the surge blocker made of amorphous cores can be reduced in size appreciably compared to the conventional ferrite surge blocker. A 350 kV, 0.05 volt-second amorphous surge blocker was designed, fabricated and tested. The amorphous core was made by winding an amorphous tape with a film for the layer insulation and was heat-treated to recover the magnetic characteristics. The core is molded by epoxy resin and installed in a FRP insulator tube filled with SF{sub 6} gas for the insulation. The volt-second measured was higher than the designed value and the electrical breakdown along the cores and between layers was not observed. This test result shows that the amorphous surge blocker is applicable for a dc acceleration power supply for high energy neutral beam injectors. (author).}
place = {Japan}
year = {1993}
month = {Oct}
}
title = {Development of an amorphous surge blocker for a high voltage acceleration power supply of the neutral beam injectors}
author = {Mizuno, Makoto, Ohara, Yoshihiro, Watanabe, Kazuhiro, and Ozaki, Akira}
abstractNote = {An amorphous surge blocker for a high voltage acceleration power supply for the neutral beam injectors has been developed. Since the saturation magnetic flux density of the amorphous core is higher than that of the ferrite core, the surge blocker made of amorphous cores can be reduced in size appreciably compared to the conventional ferrite surge blocker. A 350 kV, 0.05 volt-second amorphous surge blocker was designed, fabricated and tested. The amorphous core was made by winding an amorphous tape with a film for the layer insulation and was heat-treated to recover the magnetic characteristics. The core is molded by epoxy resin and installed in a FRP insulator tube filled with SF{sub 6} gas for the insulation. The volt-second measured was higher than the designed value and the electrical breakdown along the cores and between layers was not observed. This test result shows that the amorphous surge blocker is applicable for a dc acceleration power supply for high energy neutral beam injectors. (author).}
place = {Japan}
year = {1993}
month = {Oct}
}