Abstract
Sewage sludge samples were taken from nine differently sized sewage treatment plants at monthly intervals. The samples were analyzed for dry residues, residues on ignition, 7 heavy metal components and 15 polycyclic aromatic hydrocarbons. Assuming a normal data distribution each concentration-time sequence was assigned a coefficient of variation for determination of the variance of distribution, and the sample size, which must be known for the purpose of representative sampling, was calculated for a statistical confidence level of 90%. (orig.). [Deutsch] Aus neun Klaeranlagen unterschiedlicher Ausbaugroesse wurden in monatlichen Abstaenden Schlammproben entnommen und auf Trocken- und Gluehrueckstaende sowie Gehalte an sieben Schwermetallen und fuenfzehn PAH untersucht. Unter der Annahme normalverteilter Daten wurden jeder Konzentrations-Zeit-Reihe ein Variationskoeffizient als Streuungsmass zugeordnet und der fuer die repraesentative Probenahme erforderliche Stichprobenumfang fuer den Fall 90%iger statistischer Sicherheit errechnet. (orig.).
Osberghaus, U;
[1]
Grimmer, G;
[2]
Stoeppler, M
- Analytisches Labor, Aachen (Germany)
- Biochemisches Institut fuer Umweltcarcinogene, Grosshansdorf (Germany)
Citation Formats
Osberghaus, U, Grimmer, G, and Stoeppler, M.
Contributions to the environmental specimen bank. Pt. 8. Analysis of the concentration-time characteristics of selected sewage sludge constituents - derivation of a sampling strategy for representative sewage sludge specimens; Beitraege zur Umweltprobenbank. T. 8. Untersuchung des Konzentrations-Zeit-Profils ausgewaehlter Stoffe in Klaerschlaemmen - Ableitung einer Strategie zur Probenahme von Klaerschlaemmen definierter Repraesentanz.
Germany: N. p.,
1992.
Web.
Osberghaus, U, Grimmer, G, & Stoeppler, M.
Contributions to the environmental specimen bank. Pt. 8. Analysis of the concentration-time characteristics of selected sewage sludge constituents - derivation of a sampling strategy for representative sewage sludge specimens; Beitraege zur Umweltprobenbank. T. 8. Untersuchung des Konzentrations-Zeit-Profils ausgewaehlter Stoffe in Klaerschlaemmen - Ableitung einer Strategie zur Probenahme von Klaerschlaemmen definierter Repraesentanz.
Germany.
Osberghaus, U, Grimmer, G, and Stoeppler, M.
1992.
"Contributions to the environmental specimen bank. Pt. 8. Analysis of the concentration-time characteristics of selected sewage sludge constituents - derivation of a sampling strategy for representative sewage sludge specimens; Beitraege zur Umweltprobenbank. T. 8. Untersuchung des Konzentrations-Zeit-Profils ausgewaehlter Stoffe in Klaerschlaemmen - Ableitung einer Strategie zur Probenahme von Klaerschlaemmen definierter Repraesentanz."
Germany.
@misc{etde_10156085,
title = {Contributions to the environmental specimen bank. Pt. 8. Analysis of the concentration-time characteristics of selected sewage sludge constituents - derivation of a sampling strategy for representative sewage sludge specimens; Beitraege zur Umweltprobenbank. T. 8. Untersuchung des Konzentrations-Zeit-Profils ausgewaehlter Stoffe in Klaerschlaemmen - Ableitung einer Strategie zur Probenahme von Klaerschlaemmen definierter Repraesentanz}
author = {Osberghaus, U, Grimmer, G, and Stoeppler, M}
abstractNote = {Sewage sludge samples were taken from nine differently sized sewage treatment plants at monthly intervals. The samples were analyzed for dry residues, residues on ignition, 7 heavy metal components and 15 polycyclic aromatic hydrocarbons. Assuming a normal data distribution each concentration-time sequence was assigned a coefficient of variation for determination of the variance of distribution, and the sample size, which must be known for the purpose of representative sampling, was calculated for a statistical confidence level of 90%. (orig.). [Deutsch] Aus neun Klaeranlagen unterschiedlicher Ausbaugroesse wurden in monatlichen Abstaenden Schlammproben entnommen und auf Trocken- und Gluehrueckstaende sowie Gehalte an sieben Schwermetallen und fuenfzehn PAH untersucht. Unter der Annahme normalverteilter Daten wurden jeder Konzentrations-Zeit-Reihe ein Variationskoeffizient als Streuungsmass zugeordnet und der fuer die repraesentative Probenahme erforderliche Stichprobenumfang fuer den Fall 90%iger statistischer Sicherheit errechnet. (orig.).}
place = {Germany}
year = {1992}
month = {Nov}
}
title = {Contributions to the environmental specimen bank. Pt. 8. Analysis of the concentration-time characteristics of selected sewage sludge constituents - derivation of a sampling strategy for representative sewage sludge specimens; Beitraege zur Umweltprobenbank. T. 8. Untersuchung des Konzentrations-Zeit-Profils ausgewaehlter Stoffe in Klaerschlaemmen - Ableitung einer Strategie zur Probenahme von Klaerschlaemmen definierter Repraesentanz}
author = {Osberghaus, U, Grimmer, G, and Stoeppler, M}
abstractNote = {Sewage sludge samples were taken from nine differently sized sewage treatment plants at monthly intervals. The samples were analyzed for dry residues, residues on ignition, 7 heavy metal components and 15 polycyclic aromatic hydrocarbons. Assuming a normal data distribution each concentration-time sequence was assigned a coefficient of variation for determination of the variance of distribution, and the sample size, which must be known for the purpose of representative sampling, was calculated for a statistical confidence level of 90%. (orig.). [Deutsch] Aus neun Klaeranlagen unterschiedlicher Ausbaugroesse wurden in monatlichen Abstaenden Schlammproben entnommen und auf Trocken- und Gluehrueckstaende sowie Gehalte an sieben Schwermetallen und fuenfzehn PAH untersucht. Unter der Annahme normalverteilter Daten wurden jeder Konzentrations-Zeit-Reihe ein Variationskoeffizient als Streuungsmass zugeordnet und der fuer die repraesentative Probenahme erforderliche Stichprobenumfang fuer den Fall 90%iger statistischer Sicherheit errechnet. (orig.).}
place = {Germany}
year = {1992}
month = {Nov}
}